HEATING
MODE
Heating mode operational sequence
> 6 Min.> 3 Min.
> 6 Min.
30 sec. 30 sec.
Nominal temperature
+5 °C
Nominal temperature
+2 °C
Fan operation IT
Fan operation AT
Compressor operation AT
Actual
temperature Stop Heating mode
Heating mode
Start Heating mode
Functional diagram
Operation
Stop
Reverse flow valve
30 sec. 30 sec.
During the defrosting cycle, the indoor unit vaporiser fan and the
outdoor unit liquefier fan are switched off.
After the cycle is concluded, the fans are switched to their previous
settings.
< 7 Min.
Defrost period
15 sec. 60 sec.
Fan operation IT
Fan operation AT
Compressor operation AT Operation
Stop
Reverse flow valve
30 sec. 30 sec.
30 sec. 3 Min.
OR
Hr.
ON TIM ER
Hr.
Off TI MER
SET TEMP
Tur bo
Hr.
ON TIM ER
Hr.
Off TI MER
Tur bo
SET TEMP
MODE
Hr.
ON TIMER
Hr.
Off TIMER
Tur bo
SET TEMP
Hr.
ON TIM ER
Hr.
Off TI MER
SET TEMP
Auto
Tur bo
In the heating mode, you can simultaneously heat all of the rooms in
spring or fall. The desired room temperature is set with the /buttons
in 1 °C increments. If the room temperature is 1 °C below the selected
target temperature, the indoor unit starts to heat the air in the room.
The inverter controller checks the difference between the adjusted target
temperature and the actual room temperature.
In the event of a greater difference, a higher cooling performance is
created.
In the event of a smaller difference, a lower cooling performance is
created.
This serves to maintain the air discharge temperature and the room
temperature.
If the set room temperature is exceeded by approx. 2 °C, then the
control system turns the heating function off. To protect the compressor,
the regulation only turns the heater on again after a waiting period of
3 minutes.
In heating mode, the indoor unit fan motor is switched on after a delay,
in order to prevent the discharge of cold air.
The fins on the outdoor unit could crack at low outdoor temperatures.
Regular reversal of the cooling circuit results in a defrosting action. The
display shows "H1" during the defrosting period.
HEATING Mode
Hr.
ON TIMER
Hr.
Off TIMER
SET TEMP
Turbo
FAN
Heating mode has priority!
If an indoor unit switches
over to heating mode, then
cooling is switched off for the
other indoor devices in cooling
mode.
Cooling is not possible during
heating operation.
CAUTION
REMKO MXW
12
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for REMKO MXW520 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of REMKO MXW520 in the language / languages: English as an attachment in your email.

The manual is 1,74 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of REMKO MXW520

REMKO MXW520 User Manual - German - 28 pages

REMKO MXW520 User Manual - Dutch - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info