3 Design and function
3.1 Unit description
In cooling mode, the MVV outdoor unit (OU) serves
to output the heat extracted by the indoor unit (IU)
from the room being cooled. In heating mode, the
heat taken up by the outdoor unit can be dis-
charged by the indoor unit into the room to be
heated. In both operating modes, the output pro-
duced by the compressor precisely matches
requirements, and thereby regulates the nominal
temperature with minimal temperature deviations.
This "inverter technology" results in energy savings
over conventional split systems and also reduces
noise emissions to a particularly low level. The out-
door unit can be installed in an outdoor area or
,
providing that certain requirements are met, an
indoor area. The indoor units are designed to be
mounted high up on the wall, in an indoor area
(MVW) or for installation in suspended ceilings
(MVD) and are equipped with an electronic flow
regulator. The outdoor unit can be combined with
REMKO indoor units from the series MVW and
MVD that provide sufficient cooling capacity (see
Ä
Chapter 2.1 ‘Unit data’ on page 8). No more
than 130% of the nominal cooling output of the
indoor unit output may be installed. Operation
takes place as standard via an infra-red remote
control. The outdoor unit consists of a cycle with a
compressor, fin condenser, electronic expansion
valve and a condenser fan. The outdoor unit
cooling cycle is controlled by the controller of the
indoor unit. In order to enable operation of the unit
at low outside temperatures, a thermal
condenser pressure regulator serves as winter fan
speed control to regulate the speed of the con-
denser fan.
Refrigerant piping and distributors are used to
establish the connection between the indoor unit
and the outdoor unit.
System layout
The indoor units of unit series MVW / MVD must
always be connected to a Y-distributor or a 4-fold
distributor.
A maximum of 4Y distributors may be used per
outdoor unit and liquid or suction pipe.
With the installation of more than one indoor unit
per level, a 4-fold distributor must be used in order
to distribute the refrigerant.
Exception: Installation of 2 indoor units at the end
of the main line.
5
6
4
3
2
4
B
A
1a
7b
3
7a
8b8a
9b9a
10
1b
3
10
Fig. 7: System layout
A: Outdoor area
B: Indoor area
1 a,b: Indoor units
2: Outdoor unit
3: Condensate drainage line
4: Condenser fan
5: Outdoor unit power supply
6: Shut-off valve
7 a,b: Suction pipes
8 a,b: Liquid pipes
9 a,b: Control lines
10: Power supply to indoor units
REMKO MVV...DC
16
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for REMKO MVV 2000 DC at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of REMKO MVV 2000 DC in the language / languages: English as an attachment in your email.

The manual is 3,87 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of REMKO MVV 2000 DC

REMKO MVV 2000 DC User Manual - German - 68 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info