587702
19
Zoom out
Zoom in
Previous page
1/32
Next page
Supplementary information
for Installation
If the basic length of the
refrigerant line exceeds
5 m, add refrigerant when
commissioning the system for
the first time. (See chapter
"Add refrigerant").
Only use tools and compo-
nents designed for refrigera-
tion applications.
NOTE
Flanging tool
7 Flanging the refrigerant line
Refrigerant line
Deburrer
6 Deburring the refrigerant line
8 Correct flange shape
Tighten 1st Spanner
Counter
2nd Spanner
9 Tighten fittings
Tightening
torque:
1
4
15-20 Nm
3
8
33-40 Nm
1
2
50-60 Nm
5
8
65-75 Nm
3
4
95-105 Nm
5. Verify that the shape of the
flange is correct(figure 8).
6. First connect and hand-tighten
the refrigerant connections
to ensure they are correctly
seated.
7. Now fully tighten the fittings
using 2 suitably sized open-
ended spanners. Use one
spanner to counter the force
when tightening the fitting
(figure 9).
8. Use only diffusion-tight
insulation hoses designed for
this temperature range.
9. Lay the refrigerant lines from
the indoor unit to the outdoor
component. Ensure that they
are adequately fastened and
take measures for the oil return,
if necessary!
10.
During installation, observe
guidelines on the permitted
bending radius for the
refrigerant lines and never bend
a line twice in the same place.
Brittleness and cracking can
result.
12.
Ensure that structure-borne
sound is not transferred to
the building. Use vibration
dampers to reduce the effects
of structure-borne sound!
13.
Prepare the refrigerant lines
for the outdoor component as
described above.
11.
Use the wall or floor brackets to
fasten the outdoor component
where structurally allowed
(refer to the installation
instructions for the brackets).
19
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for REMKO ML262 DC at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of REMKO ML262 DC in the language / languages: English as an attachment in your email.

The manual is 1,92 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of REMKO ML262 DC

REMKO ML262 DC User Manual - German - 32 pages

REMKO ML262 DC User Manual - German - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info