ML 260 ML 350 ML 520 ML 680
Nominal cooling capacity* kW 2.59 3.50 5.27 6.80
Energy efficiency class cooling C C D D
Energy efficiency ratio
EER 2.82 2.82 2.61 2.61
Operational area (
size of room), approx. 80 110 160 230
Refrigerant R 407C
Injection pipe connection
Inches
(mm)
1/4 (6.35) 3/8 (9.52)
Suction pipe connection
Inches
(mm)
3/8 (9.52) 1/2 (12.7) 5/8 (16.0)
Refrigerant pipe, length max. m 10 15
Refrigerant pipe, height max. 5 8
Refrigerant, base quantity g 680 1050 1700 1730
Refrigerant, additional amount > 5 m g/m 15 20 30 35
Power supply V/Ph/Hz 230 / 1~ / 50
Nominal power consumption cooling * kW 0.92 1.24 2.02 2.61
Nominal current consumption cooling* A 4.35 5.55 10.58 13.45
Respective indoor unit ML 260-IT ML 350-IT ML 520-IT ML 680-IT
Operating range °C +16 to +32
Circulating air volume per speed /h 270/320/400 330/410/500 500/610/750 600/730/900
Protection type IP X0
Sound pressure level per speed ** dB(A) 33 / 36 / 41 35 / 38 / 42 36 / 40 / 44 38 / 41 / 46
Dimensions height mm 268 286 326
width mm 788 886 1096
depth mm 180 180 215
Weight kg 8 9 15 15
Respective outdoor unit ML 260-AT ML 350-AT ML 520-AT ML 680-AT
Operating range °C +21 to +45 (with optional winter regulation -10 to +45)
Circulating air volume, max. m³/h 1620 1740 2520 3600
Protection type IP X4
Sound pressure level, max. ** dB(A) 50 51 54 58
Dimensions height mm 543 548 605 730
width mm 645 700 805 860
depth mm 265 275 305 325
Weight kg 29 35 53 76
Serial number 700.... 701.... 702.... 703....
Ref. number 1618260 1618350 1618520 1618680
Power consumption in 500 hours kWh 460 620 1010 1305
Technical Data
* Room temperature DB 27°C, WB 19°C; outside temperature DB 35°C, WB 24°C
** Distance 1m
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for REMKO ML260 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of REMKO ML260 in the language / languages: English as an attachment in your email.

The manual is 1,24 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of REMKO ML260

REMKO ML260 User Manual - German - 28 pages

REMKO ML260 User Manual - Dutch - 24 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info