Error indicated by flashing code
Installation instructions for qualified personnel
Important points prior to
installation
Transport the unit in its original
packaging as close as possible
to the installation location.
This avoids transportation
damage.
Check that the packaged
contents are complete and
inspect the unit for any visible
signs of transportation damage.
Notify any deficiencies to
the contractual partner and
forwarding agent.
Lift the unit by its corners
and not the refrigerant or
condensation connections.
Insulate the refrigerant pipes
(injection and suction pipe),
valves and connections to make
them tight against vapour
diffusion. If necessary, also
insulate the condensation pipe.
Select an installation location
which allows air to freely
flow through the inlet and
outlet. (see section "Minimum
clearances").
Do not install the unit
adjacent to any hotspots. Unit
performance will be impaired if
installed next to hotspots.
Only open the stop valves
for the refrigerant pipes after
installation has been fully
completed.
Use caps or adhesive tape to
seal off the
open refrigerant pipes and
prevent the ingress of humidity.
Never kink or push in the
refrigerant pipes.
Avoid unnecessary bending.
This minimises the pressure
loss in the refrigerant pipes and
ensures that the compressor
oil can flow back without
obstruction.
Special measures concerning
the oil return pipe must
be taken if the outdoor
components is mounted above
the indoor unit.
See section "Oil return
measures".
Add refrigerant if the basic
length of the refrigerant pipe
exceeds 5 metres. The amount
of additional refrigerant is
given in the chapter "Adding
refrigerant".
Only use the union nuts
supplied with the refrigerant
pipes. These should only
be removed shortly before
connecting the refrigerant
pipes.
Establish all electrical
connections is accordance with
the relevant DIN- and VDE
standards.
Ensure the electrical cables
are properly connected to the
terminals, otherwise there is a
risk of fire.
Display Cause Required action
E1 Faulty circulation sensor in indoor unit Contact specialist dealer
E2 Faulty frost protection sensor in indoor unit Contact specialist dealer
E4
Cooling mode: No cooling output after 30 min.
Heating mode> No heating output after 30 min.
Contact specialist dealer
E5
Cooling mode: Frost protection has tripped
Heating mode> Overheating protection has tripped
Contact specialist dealer
E6 Break in internal control cable jumper Check jumper connector
15
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for REMKO ML 521 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of REMKO ML 521 in the language / languages: English as an attachment in your email.

The manual is 4,3 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of REMKO ML 521

REMKO ML 521 User Manual - German - 28 pages

REMKO ML 521 User Manual - Dutch - 28 pages

REMKO ML 521 User Manual - French - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info