Combined TIMER (setting "TIMER ON" and
"TIMER OFF" at the same time)
"TIMER OFF ð "TIMER ON"
(On ð Stop ð Start)
Example:
Y
ou want the air conditioning unit to switch off in
two hours from the time it was programmed, and
switch back on ten hours later.
1. Press the "TIMER OFF" key.
2. Press the "TIMER OFF" key again until the
desired stop time is shown in the "TIMER
OFF" area on the remote control.
3. Press the "TIMER ON" key.
4. Press the "TIMER ON" key again until "10H"
is shown in the "TIMER ON" area on the
remote control.
5. Wait for 3 seconds and the temperature
appears again in this area of the digital dis-
play. The "TIMER ON" and "TIMER OFF"
indicators stay lit, and this function is acti-
vated.
On
Set time
Stop
Start
2 hours later
after setting
10 hours later
after setting
Fig. 16: "TIMER OFF" / "TIMER ON" example
"TIMER ON ð
"TIMER OFF"
(Off ð Start ð Stop)
Example:
You want the air conditioning unit to switch on in
two hours from the time it was programmed, and
switch back off five hours later.
1. Press the "TIMER ON" key.
2. Press the "TIMER ON" key again until "2.0H"
is shown in the "TIMER ON" area on the
remote control.
3. Press the "TIMER OFF" key.
4. Press the "TIMER OFF" key again until
"5.0H" is shown in the "TIMER OFF" area on
the remote control.
5. Wait for 3 seconds and the temperature
appears again in this area of the digital dis-
play. The "TIMER ON" and "TIMER OFF"
indicators stay lit, and this function is acti-
vated.
Off
Set time
Stop
Start
2 hours later
after setting
5 hours later
after setting
Fig. 17: "TIMER ON" / "TIMER OFF" example
REMKO ML series
20
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for REMKO ML 355 DC at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of REMKO ML 355 DC in the language / languages: English as an attachment in your email.

The manual is 3,53 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of REMKO ML 355 DC

REMKO ML 355 DC User Manual - German - 68 pages

REMKO ML 355 DC User Manual - Dutch - 68 pages

REMKO ML 355 DC User Manual - French - 72 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info