6 Commissioning
Before every commissioning the air inlet and outlet
openings should be checked for foreign bodies and
the air inlet filter must be checked for dirt. Blocked
or soiled grills and filters must be cleaned immedi-
ately, see "Care and maintenance" chapter.
Cooling mode
1. Switch the unit on with the "I/O" key
.
2. Select cooling mode with the "MODE" key
.
3. Set the desired target temperature with the
"THERMO/TIMER CONTROL" keys. The
selected target temperature will be shown in
the display
. If the fan speed selected is too
large or too small then this can be adjusted
with the "FAN" key.
Recirculation mode
1. Switch the unit on with the "I/O" key
.
2. Select recirculation mode with the "MODE"
key
.
7 Shutdown
NOTICE!
Never switch of
f the equipment by pulling out
the mains plug.
Temporary shutdown
If it is planned to shut down the unit for longer
periods e.g. during the winter
, proceed as follows:
1. Let the unit run in recirculating operation for
ca. 2 hours in order to dry the surfaces of the
evaporator fins. This will transport the
remaining moisture out of the unit and this
will avoid unpleasant odours when the unit is
re-commissioned.
2. Switch the unit of
f with the "I/O" key, pull out
the power plug and wind up the power
supply. Ensure that the cable is not kinked or
too severely bent. The line can be fastened
to the rear of the unit.
3. Place a suitable container underneath the
condensate drain of the internal reservoir
.
The condensate drain is located on the lower
rear side of the unit.
4. Pull out the stopper from the condensate
drain and collect the condensate that drains
out.
5. Then insert the stopper once again. A
missing stopper or an incorrectly inserted
stopper will result in condensate leaking out
after re-commissioning.
6. Store the unit in an upright position in a cool,
dry and dust-free location protected from
direct sunlight. Cover the unit with a synthetic
cover to protect it against dust if desired.
Permanent shutdown
The entire system should only be dismantled by a
specialist firm familiar with all environmental
aspects involved. REMKO GmbH & Co. KG or your
contractual partner will be pleased to provide a list
of refrigerant specialists in your area.
17
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for REMKO MKT 295 Eco at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of REMKO MKT 295 Eco in the language / languages: English as an attachment in your email.

The manual is 2,47 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of REMKO MKT 295 Eco

REMKO MKT 295 Eco User Manual - German - 28 pages

REMKO MKT 295 Eco User Manual - Dutch - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info