Conduct the warm exhaust air away
NOTICE!
The exhaust air hose should always be laid
rising in the direction of air flow and must not be
extended!
In cooling mode the unit creates warm moist
exhaust air
, which must be conducted away from
the room to be cooled. For this reason it is neces-
sary to plug the exhaust air hose into the outlet
opening on the rear of the unit.
n Ensure that the catches for the exhaust air
hose latch securely into the two openings of
the connection aperture. Do not lay the flexible
exhaust air hose with tight bends and do not
kink it in order to be sure of ef
fective operation
and to avoid this causing damage to air ducting
components!
Fig. 8: Latch the hose into place
n The exhaust air of the unit contains a certain
amount of moisture. For this reason it is advis-
able to feed the exhaust air to the outdoor area
or to outdoors.
Exhaust air routing variants
You can route the exhaust air out of the building as
follows:
Via a flat nozzle
The flat nozzle supplied can be used in various dif-
ferent ways. It is possible to feed the flat nozzle
through an open window and fasten it by means of
Velcro and a window suction cup (Fig. 9). Likewise
the flat nozzle can be hung in a tilted window
(Fig. 10).
Via a wall pass-through
The hose supplied is firmly attached to a wall pass-
through. A suitable wall pass-through is available
as an accessory (Fig. 1
1).
Fig. 9: Exhaust air with open window
Fig. 10: Exhaust air with tilted window
Fig. 11: Wall pass-though
NOTICE!
In some circumstances routing the exhaust air
via a firmly attached exhaust air hose, e.g.
through closed doors or windows, can lead to
negative pressure in the room in which the unit
is being used. If this should reduce the perform-
ance of the unit then arrange for the pressure to
be equalised (provide ventilation if necessary
on-site).
REMKO MKT ECO series
16
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for REMKO MKT 255 Eco S-Line at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of REMKO MKT 255 Eco S-Line in the language / languages: English as an attachment in your email.

The manual is 2,47 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of REMKO MKT 255 Eco S-Line

REMKO MKT 255 Eco S-Line User Manual - German - 28 pages

REMKO MKT 255 Eco S-Line User Manual - Dutch - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info