5.5 Condensate removal
In cooling mode:
The unit is equipped with automatic drainage of the
condensate water that arises while in cooling
mode. For this purpose, the water that arises is
collected in the condensate tray of the unit and dis-
persed by a pump on the condenser. Here, it evap-
orates and is fed outside with the aid of the
exhaust air.
If the unit is operated for a prolonged period of
time, or if it is operated at a very high outdoor air
humidity, it is possible that the quantity of conden-
sate water that arises is greater than the quantity
that can be evaporated. In this case, the unit
switches off via the integrated liquid level switch
and “OF” appears on the display.
NOTICE!
It is recommended to provide continuous con-
densate drainage even for cooling mode.
Beneath the unit there is a condensate drainage
connection for the permanent condensate drainage
connection and a T-piece with a closed emergency
drainage nozzle. Both connections are sealed at
the factory with a rubber stopper.
NOTICE!
In heating mode, automatic discharge through
evaporation is not possible and a permanent
condensate drain is absolutely necessary.
Emergency drainage
Hold a container (with a min. container capacity of
3 litres) beneath the unit and open the emergency
drainage to discharge. Then close off the emer-
gency drainage nozzle with the rubber stopper.
2
1
Fig. 8: Condensate removal
1: Emergency drainage nozzle
2: Connection for permanent discharge (13 mm)
17
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for REMKO KWT 240 DC at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of REMKO KWT 240 DC in the language / languages: English as an attachment in your email.

The manual is 3,17 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of REMKO KWT 240 DC

REMKO KWT 240 DC User Manual - German - 32 pages

REMKO KWT 240 DC User Manual - Dutch - 32 pages

REMKO KWT 240 DC User Manual - French - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info