587983
30
Zoom out
Zoom in
Previous page
1/60
Next page
Condensate drainage connection
A condensate drip pan must be
mounted under the unit to drain
any condensate that occurs.
The on-site condensate line
must be laid with a slope of at
least 2%.
If necessary, provide vapour-
diffusion-tight insulation.
In case of an operation of
the unit under 4°C outdoor
temperature, a frost-free laying
of the condensate line must be
observed. The lower housing
cladding and condensate drip
pan must also be kept frost-
free to guarantee permanent
draining of the condensate.
If necessary, an accompanying
pipe heater must be provided.
After laying, the free drain-
age of the condensate must be
checked and permanent seal
tightness must be guaranteed.
+
+
+
+
+
+
Condensate drainage
Condensate drip pan
Condensate drainage
Under certain weather
conditions, a growing icing can
develop at the bottom of the
fin heat exchanger. To prevent
this formation of ice, we
recommend that you keep the
heat exchanger free of frost on
both sides, for example, using
a strip heater.
NOTE
Condensate connection
and safe drainage
Secured drainage in case of leaks
Regional regulations or laws
governing environmental
protection, such as a local water
ecology act (Wasserhaushaltgesetz
(WHG) in Germany), can
require suitable measures for
the prevention of unmonitored
drainage in case of a leak in order
to
dispose of emerging refrigerator oil
or potentially hazardous
substances safely.
REMKO KWG
30
30


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for REMKO KWG750 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of REMKO KWG750 in the language / languages: English as an attachment in your email.

The manual is 7,1 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of REMKO KWG750

REMKO KWG750 User Manual - German - 60 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info