System setup
Operation
The unit is conveniently operated
using the fully automatic iChiLL
controller. If programming using
the indoor controller is possible only
with difficulty due to local condi-
tions, the unit can also be actuated
using the cabled remote control
(accessory) or an external, floating
enabling contact (serial equipment).
The standard equipment includes
a collective fault contact for the
external indication of a fault.
If the letter "A" with a two-
digit numeric code appears on
the display,
the chiller is malfunctioning
(See the "Troubleshooting and
customer service" chapter).
ATTENTION
The unit is designed for
a 2-pipe system.
The system has 2 medium pipes
(pipes for inlet flow and return) for
cooling with cold medium (KWG)
or for heating with hot medium
(units with heat pump function
(KWP)).
In combination with a correspond-
ing system, it is possible to intro-
duce the generated power to the
rooms being cooled through the
floor, building structure, or chilled
sails.
For all system variants, a minimum
volume flow rate and minimum
medium volume of the system
must be ensured.
Chiller
System setup
Medium inlet
Medium outlet
Indoor area 1
Outdoor area
Indoor area 2 Indoor area 3
Room temperature controller
Infrared remote control Cabled remote control
Cold water
consumer
Cold water
consumer
Cold water
consumer
Condensate line
Condensate line (only
units with heat pump
function)
Condensate line Condensate line
Collective condensate line
Operating possibilities
Collective
fault indicator
IPro controller
Cabled
remote control
Enabling contacts
ON/OFF Cooling/heating
(e.g., GLT)
(Serial equipment)
(Serial equipment)
(Accessory)
(Serial
equip-
ment)
Help save energy consumption
in standby mode! If the unit,
system, or components are not
used, we recommend that the
power supply be disconnected.
Safety-related components are
not subject to our recommen-
dation!
TIP
7
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for REMKO KWG750 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of REMKO KWG750 in the language / languages: English as an attachment in your email.

The manual is 7,1 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of REMKO KWG750

REMKO KWG750 User Manual - German - 60 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info