726827
20
Zoom out
Zoom in
Previous page
1/52
Next page
"FAN" mode
Press the "MODE" key once or repeatedly to
switch to recirculation mode. In this mode, the unit
is used as an air circulation unit. The room is nei-
ther heated nor cooled.
This mode allows the heat trapped under the
ceiling to be circulated to the lower regions of
the room in winter
.
MODE
UMLUFTBETRIEB
MODE
CIRCULATION MODE
Fig. 16: "FAN" mode
"HEAT" mode
Press the "MODE" key once or repeatedly to
switch to heating mode. Use this mode to heat the
room air to the desired target temperature. The
prerequisite for this is that suf
ficient heat is present
in the cold water system.
Press the "TEMP
/ " key to set the desired
room temperature in 1 °C steps. If the room tem-
perature is below the set target temperature, the
three-way valve provided by the customer opens. If
there is suf
ficient heating medium available, the
indoor unit starts to warm up the air in the room. If
the actual temperature rises approx. 1 °C above
the set room temperature, the controller switches
the valve off.
Cooling mode:
W
e recommend setting the target temperature
to max. 6 °C below the outside temperature.
The automatic fan speed and swing functions
should also be used.
Heating mode:
The fan will only start when the fin temperature
reaches 38°C.
Heating mode:
W
e recommend setting the target temperature
to max. 28°C. Maximum fan speed and the
lowest fin setting should also be used.
MODE
HEIZBETRIEB
MODE
HEATING MODE
Fig. 17: "HEAT" mode
REMKO KWD
20
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for REMKO KWD serie 25-35-45-55-70-85-100 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of REMKO KWD serie 25-35-45-55-70-85-100 in the language / languages: English as an attachment in your email.

The manual is 4,47 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of REMKO KWD serie 25-35-45-55-70-85-100

REMKO KWD serie 25-35-45-55-70-85-100 User Manual - German - 52 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info