587878
10
Zoom out
Zoom in
Previous page
1/20
Next page
10
REMKO ETF 360/460
Automatic defrost system
The moisture contained in the
room air condenses when cooling
and coats the evaporator fins
with rime or ice depending on the
air temperature and the relative
humidity (% RH).
The automatic defrost system that
is integrated in the unit switches the
defrost cycle on if required.
The rime or ice that has
accumulated on the exchanger
surfaces is defrosted using heat gas
as required.
This defrosting method is particularly
fast and effective, and guarantees
high dehumidification performance.
Dehumidification mode is only
paused for a short time during the
defrost phase.
The [] indicator light indicates
that the heat gas defrost cycle is
active.
Emptying the condensate container
Depending on the amount of
condensate, the integrated
condensate container must be
emptied from time to time.
If the condensate container is full,
unit operation is stopped and the
[] “Container full” indicator
light flashes to indicate this unit
condition.
1. Pull the full container forwards
and out carefully.
2. Empty the container in
a suitable location.
s
s
s
Activating the timer
You can use the timer function
to preselect automatic unit “ON/
OFF” switching functions for up to
24 hours (in 1 hour cycles).
Timer switching functions
Setting in running operation:
After the selected number of
hours, the unit switches OFF.
Setting
if the unit is switched off
(the power plug must be plugged
in to a mains socket):
After the selected number of
hours, the unit switches ON.
You can use the [] key to
activate the timer function
and the [] keys to select the
required times in 1 hour steps
(maximum of 24 hours).
The entries flash on the display []
for around 10 seconds.
Timer activation is indicated
continuously by the indicator
light [] on the control panel.
If the room temperature is
sufficiently high (approx.
20 °C), rime is generally
not formed on the fin
surface, rendering defrosting
unnecessary.
Therefore, the air dehumidifier
works economically.
NOTE
The unit can only be started up
again once the condensate container
has been inserted correctly.
NOTE
The unit can be operated via
an external timer if necessary.
NOTE
After being emptied, the
condensate container incl.
float must be checked for
damage, contamination etc.
NOTE
If the unit is switched on via
the power key, all set data is
retained if the power supply is
disconnected.
NOTE
3. Re-insert the emptied and
checked container carefully into
the unit.
The “Container full” indicator
light extinguishes and the unit
continues to run automatically.
(Observe the switch-on delay)
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for REMKO ETF360 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of REMKO ETF360 in the language / languages: English as an attachment in your email.

The manual is 4,77 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of REMKO ETF360

REMKO ETF360 User Manual - German - 20 pages

REMKO ETF360 User Manual - Dutch - 20 pages

REMKO ETF360 User Manual - French - 20 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info