REMKO ETF 360/460
Safety notes
Condensation heat
The Energy transferred to the air
from the condenser consists of:
1. The amount of heat derived
beforehand in the evaporator.
2. The electrical drive energy.
3. The condensation heat released
by liquefying the water vapour.
Energy must be supplied when
liquid is converted into a gas.
This energy is designated as
evaporation heat. It does not
cause any increase in temperature,
but is required to convert a liquid
into a gas. Conversely, energy is
released when gas is liquefied,
this is designated as condensation
heat.
The amount of energy from
evaporation heat and condensation
heat is the same.
For water, this is:
2250 kJ/kg (4.18 kJ = 1kcal)
From this it is evident that the
condensation of water vapour
causes a large quantity of energy
to be released.
If the moisture that it is to be
condensed is not introduced by
evaporation in the room itself,
but from outside, e.g. through
ventilation, the condensation
heat released contributes to
the heating of the room. With
drying operations, a heat cycle
is created, whereby heat is
consumed for evaporation
and released for condensation.
When dehumidifying fed air,
a larger contribution of heat is
created, which manifests itself as
a temperature increase.
Generally speaking, the time
required for the drying process is
not only dependent on the output
of the unit, but is determined to
a greater extent by the speed at
which the material or building
section loses its moisture.
The units have been subjected to
extensive material, functional and
quality inspections prior to delivery.
However, dangers can result
from the units if they are used
improperly or not as intended by
untrained personnel.
The following notes
must be observed in full:
The units may not be installed
or operated in explosive
environments
The units must not be installed
or operated in atmospheres
containing oil, sulphur, chlorine,
salt or dust
Never stick foreign objects into
the units
The units must not be exposed
to direct jets of water
An unobstructed air inlet and
air outlet must be guaranteed
at all times
The air-inlet grille must always
be kept free of dirt and loose
objects
The units must not be covered
during operation
The units must be installed
upright and in a stable position
The units must not be
transported while they are
running
The units may only be
transported upright (water will
escape otherwise)
All electrical cables on the
outside of the units must be
protected against damage (e.g.
by animals etc.)
Before each change of location,
the condensate container must
be emptied
CAUTION
Extensions to the connection
cable must only be conducted
by authorised specialist
electricians, taking into
consideration the unit power
consumption, cable length and
local use.
CAUTION
Work on the refrigerant
system and on the electrical
equipment must only be
conducted by a specially-
authorised specialist!
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for REMKO ETF360 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of REMKO ETF360 in the language / languages: English as an attachment in your email.

The manual is 4,77 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of REMKO ETF360

REMKO ETF360 User Manual - German - 20 pages

REMKO ETF360 User Manual - Dutch - 20 pages

REMKO ETF360 User Manual - French - 20 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info