794468
14
Zoom out
Zoom in
Previous page
1/28
Next page
14
REMKO series ETF Eco
Set-up
For the best economic and safe use
of the units, the following notes
must be followed in full:
The units must be set up in an
upright and level position, to
ensure that the condensate can
drain freely
To ensure optimum air
circulation, the units should be
set up in the centre of the room,
where possible
Ensure that the room air can
be sucked in and discharged
without hindrances
Observe a minimum clearance
of 50 cm from walls
Units must never be set up in
the immediate vicinity of heaters
or other sources of heat
Air circulation is improved if the
unit is set up approx. 1 m above
the ground
The room being dried or
dehumidified must be closed to
the surrounding atmosphere
Avoid having opened windows
and doors etc., and avoid
frequent entry to or exit from
the room as much as possible
The units may not be used
in environments containing
a great deal of dust or chlorine,
or in places with atmospheres
containing ammonia
The output of the unit is entirely
dependent on the conditions
inside the room, room
temperature, relative humidity
and observance of the set-up
instructions
Wall clearance
min. 0.5 m
Maintain adequate clearance from
heaters or other sources of heat.
Keep windows and doors closed!
Schematic depiction of how to set up the REMKO air dehumidifier
Commissioning
Before commissioning the unit or if
local requirements dictate, the air-
inlet grill and air-outlet grill must
be checked for contamination.
Important notes
prior to commissioning
Never use the mains cable as
a pull cord
After being switched on,
the units operate fully-
automatically until switched off
by the hygrostat or liquid level
switch when the condensate
container is full
The condensate container must
be inserted properly
The unit cannot be operated if
the condensate container is not
inserted properly!
If the units work in continuous
operation with an external
condensate drainage
connection, refer to the
relevant section on page 11
NOTE
A contaminated grille or filter
must be cleaned or replaced
immediately.
In order to prevent damage to
the condenser, the units are
equipped with a mechanism
that prevents the compressor
from being immediately
switched back on after it is
switched off.
The compressor does not switch
back on until after a waiting
time of approx. 3 minutes!
NOTE
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for REMKO ETF-460 Eco at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of REMKO ETF-460 Eco in the language / languages: English as an attachment in your email.

The manual is 3.28 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of REMKO ETF-460 Eco

REMKO ETF-460 Eco User Manual - German - 28 pages

REMKO ETF-460 Eco User Manual - Dutch - 28 pages

REMKO ETF-460 Eco User Manual - French - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info