Unit description
Operating sequence
The unit is ready for operation
when the power key is pressed.
The integrated hygrostat controls
the unit’s operation according to
the settings.
In dehumidification mode, the fan
extracts the moist room air through
the intake grill withlter, evaporator
and the condenser behind.
Heat is removed from the room air
on the cold evaporator. The air is
then cooled to below dew point.
The water vapour contained in
the room air is then deposited
as condensate or rime on the
evaporator fins.
On the condenser (heat
exchanger), the cold and
dehumidified air is warmed up
again and discharged back into
the room via the outlet grill
with a temperature increase of
around 5 - 10 °C above the room
temperature.
The processed, dry air then re-
mixes with the room air.
Continuous circulation of the room
air through the unit gradually
reduces the relative humidity
(% RH) in the room to the desired
humidity level.
Depending on the room air
temperature and the relative
humidity, condensed water will
drip into the condensate trap and
then into the condensate container
below either continuously or only
during the defrosting phases.
A float is installed inside the
condensate container. In the event
that the container is full, the float
will activate a microswitch which will
switch off dehumidification mode.
The units switch off and the
“container full” indicator light on
the control panel flashes.
This extinguishes again when the
empty condensate container is re-
inserted.
Dehumidification mode then starts
after a switch-on delay of around
3 minutes depending on the
requirements.
In unattended continuous
operation with an external
condensate connection, the
condensate that occurs is
drained continuously via a hose
connection or pumped out using
the integrated condensate pump if
required.
The units have been designed for
universal and straightforward air
dehumidification.
Their compact dimensions allow
the unit to be transported and set
up with ease.
The units operate in accordance
with the condensation principle
and are equipped with
a hermetically sealed refrigerant
system, heat gas defrosting, low-
noise and low-maintenance fan
and connection cable with plug.
Fully-automatic operation,
a condensate container with
integrated overflow protection
in addition to connection ports
for direct condensate drainage or
a condensate pump connection
help to ensure continuous fault-
free operation.
The units conform to the
fundamental health and safety
requirements of the appropriate
EU stipulations.
The units are dependable and offer
ease of operation.
The units are used in all locations,
where dry air is a must and where
economic consequential damage
(such as that caused by mould)
must be prevented.
The units may be used for the
drying and dehumidification of
areas such as:
Living rooms, bedrooms,
shower rooms or cellar rooms
Laundry rooms, weekend
homes, caravans
Warehouses and laboratories
Bathrooms, wash rooms and
changing rooms etc.
Cellar rooms, storage rooms
Condensate container
Condenser
Evaporator
Compressor
Schematic depiction of the workings of the REMKO air dehumidifier
Moist room air
Dehumidified
room air
Recirculating fan
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for REMKO ETF-460 Eco at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of REMKO ETF-460 Eco in the language / languages: English as an attachment in your email.

The manual is 3.28 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of REMKO ETF-460 Eco

REMKO ETF-460 Eco User Manual - German - 28 pages

REMKO ETF-460 Eco User Manual - Dutch - 28 pages

REMKO ETF-460 Eco User Manual - French - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info