587583
17
Zoom out
Zoom in
Previous page
1/32
Next page
Selection of installation location
Indoor unit
The indoor unit is designed for
horizontal wall installation above
doors. However, it can also be
used in the upper wall area
(min. 1.75 m above the floor).
The indoor unit is not suitable for
installation on roof inclines.
Outdoor component
The outdoor component is
designed for horizontal installation
on a base in outdoor areas.
The installation site must be level,
flat and firm. The unit should also
be secured to prevent toppling.
The outdoor component can be
set up outside as well as inside
a building. For external installation,
please observe the following
notes to protect the unit from the
influence of the weather.
Rain
For attic or roof set up, the unit
should be installed with at least
10 cm ground clearance. A floor
bracket is available as an optional
accessory.
Sun
The condenser on the outdoor
component emits heat.
Exposure to direct sunlight will
further increase the temperature
of the fins and reduce the
heat output of the finned
heat exchanger. The outdoor
component should be installed on
to the north side of the building
whenever possible. If necessary,
take measures to provide sufficient
shade (responsibility of customer).
One possible solution is to build
a small roof. These measures
should not affect the flow of warm
outlet air.
Wall openings
A wall opening of at least
70 mm diameter and 10 mm
incline from the inside to the
outside must be made for each
indoor unit.
We recommend that the inside
of the opening is padded or
lined, e.g. using a PVC pipe,
to prevent the lines being
damaged.
After installation, the wall
opening should be closed off
with a suitable sealant. Do not
use materials containing cement
or lime!
Installation materials
The indoor unit is attached to
the wall by a wall bracket and
4 screws (to be provided by the
customer).
The outdoor component is
attached by 4 screws and a wall
bracket to the wall or fixed by
a floor bracket to the ground.
Windbreak
Wind
Lines in the wall opening
Control cable
Condensate line
Injection pipe
Suction line
PVC pipe
Wind
If the unit is being installed in
windy areas, ensure that the
warm outlet air discharges in the
prevailing wind direction. If this
is not the possible, it may be
necessary to install a windbreak
(to be provided by the customer).
Ensure that the windbreak does
not adversely affect the air intake
to the unit.
Snow
The unit should be wall-mounted
in areas of heavy snowfall.
Installation should then be at least
20 cm above the expected level
of snow to prevent snow from
entering the outdoor component.
An optional wall bracket is
available as an accessory.
Minimum clearance to snow
20 cm
Snow
17
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for REMKO BL351 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of REMKO BL351 in the language / languages: English as an attachment in your email.

The manual is 4,4 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of REMKO BL351

REMKO BL351 User Manual - German - 28 pages

REMKO BL351 User Manual - German - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info