587582
29
Zoom out
Zoom in
Previous page
1/32
Next page
29
Technical data
Series BL 261 BL 351
Operating mode Wall / room air conditioner combination for cooling and heating
Nominal cooling output 1) kW 2.69 3.59
Nominal heating output 2) kW 2.96 4.24
Energy efficiency rating, cooling 1) A A
Energy efficiency ratio EER 1) 3.32 3.23
Energy efficiency rating, heating 2) A A
Energy efficiency ratio COP 2) 3.70 3.66
Power consumption, yearly, (500h) C/H kWh 405 / 400 555 / 580
Operating range (room volume), approx. 80 110
Refrigerant R 410A 4)
Operating pressure, max. kPa 4200 / 4200
Power supply V/Hz 230 / 1~ / 50
Nom. electrical power consumption, cooling 1) kW 0.81 1.11
Electrical rated power consumption, heating 2) kW 0.80 1.16
Electrical rated power consumption, cooling 1) A 3.60 4.99
Electrical rated power consumption, heating 2) A 3.61 5.32
Electr. starting current, max. A 21 28
Max. operating pressure kPa 4200 / 4200
Data specific to indoor unit BL 261 IT BL 351 IT
Adjustment range, room temperature °C +16 to +31
Operating range °C +15 to +31
Air flow volume per speed setting m³/h 320/370/420 380/450/520
Sound pressure level per speed setting 3) dB(A) 30/34/38 32/36/40
Protection class IP X0
Condensate draining mm 17 17
Dimensions - height mm 275 275
width mm 790 790
depth mm 200 200
Weight kg 8,0 10,0
Data specific to outdoor component BL 261 AT BL 351 AT
Operating range, cooling °C +7 to +48
Operating range, heating °C -7 to +25
Air flow rate, max. m³/h 1925 2050
Protection class IP 24
Sound pressure level, max. 3) dB(A) 52 53
Refrigerant, basic capacity kg 0.70 1.00
Refrigerant pipe, length approx.
series / accessories m 2 / 10
Refrigerant pipe, height, max. m 5
Dimensions - height mm 540 540
width mm 780 780
depth mm 250 250
Weight kg 30,0 34,0
Serial number 801... 807...
EDP no. 1630365 1630360
1) Air inlet temperature TK 27°C / FK 19°C, outdoor temperature TK 35°C, FK 24°C, max. air flow rate
2) Air inlet temperature TK 20°C, outdoor temperature TK 7°C / FK 6°C, max. air flow rate
3) Distance 1m free field
4) Contains greenhouse gas according to Kyoto protocol
29


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for REMKO BL261 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of REMKO BL261 in the language / languages: English as an attachment in your email.

The manual is 4,4 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of REMKO BL261

REMKO BL261 User Manual - German - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info