Fault display on the indoor unit
Display Error description
E0 EEPROM error, indoor unit
E1 Communication error between indoor unit and outdoor unit
E3 Fan speed control indoor unit disabled
E4 Room temperature probe T1 defective
E5 Temperature probe, evaporator T2 defective
F0 Overflow protection
F1 Temperature probe air inlet outdoor unit T4 defective
F2 Temperature probe, evaporator outlet T3 defective
F3 Temperature probe, heat gas line T5 defective
F4 EEPROM error, outdoor unit
F5 Condenser fan speed control probe not working
P0 Compressor actuation error
P1 Over-voltage or under-voltage error
P2 Compressor overheating protection (heat gas temperature too high)
P4 Inverter control disabled
P5 Mode Conflict (indoor units set in different operating modes)
P6 Probe low pressure outdoor unit is aktivated
EC No cooling capacity after 30 minutes
dF Defrosting
For fault elimination refer to troubleshooting on the following pages.
1
1.2 Indoor unit fault analysis
Error code: E0 / F4
Reason: The control board of the outdoor unit or indoor unit cannot read the unit memory
(EEPROM)
Cause:
n Installation error
n Control boards of outdoor unit or indoor unit defective
Switch off voltage, switch on again 2 minutes
later
. Is the error still present?
YES
Replace the circuit boards of the outdoor unit
and indoor unit in turn, in order to locate the
defective EEPROM
43
43


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for REMKO ATY 266 DC at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of REMKO ATY 266 DC in the language / languages: English as an attachment in your email.

The manual is 3,76 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of REMKO ATY 266 DC

REMKO ATY 266 DC User Manual - German - 64 pages

REMKO ATY 266 DC User Manual - Dutch - 64 pages

REMKO ATY 266 DC User Manual - French - 68 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info