This shows that the rate of corro-
sion below 50% relative humidity
(R H) is insignificant and below
40% R H can be disregarded.
From 60% R H, the rate of corro
-
sion increases considerably. This
moisture damage limit applies also
to numerous other materials, e.g.
powders, packaging, wood or elec-
tronic units.
Buildings can be dried out in differ
-
ent ways:
1. By heating and air exchange:
The room air is heated to absorb
moisture in order to then be dis
-
charged to the atmosphere. The
total input energy is lost with
the discharged, moist air.
2. By dehumidification:
The moist air in an enclosed
room is continuously dehumidi-
fied by the condensation princi-
ple.
The interrelated processes that
take place during dehumidification
are based on physical laws.
These are to be illustrated here in
simplified form in order to explain
the principle of dehumidification.
The use of
REMKO dehumidifiers
No matter how well windows
and doors are insulated, damp
and moisture can penetrate
even through thick concrete
walls.
The water volumes required for
binding concrete, mortar, plas
-
ter, etc. are diffused out initially
after 1-2 months under certain
circumstances.
Even moisture that has penetrat
-
ed masonry following high wa-
ter or flooding, is only released
very slowly.
This applies similarly, e.g. also to
moisture contained in deposited
materials.
The moisture (water vapour) es
-
caping from buildings or materials
is absorbed by the ambient air. This
increases their moisture content
and ultimately results in corrosion,
mould, rot, peeling of paint coat
-
ings and other unwanted moisture
damage.
The diagram opposite shows an
example of the rate of corrosion,
e.g. for metal at different humidity
levels.
Dehumidification
In terms of energy consumption,
dehumidification has one decisive
advantage:
Energy expenditure is restricted
solely to the existing room volume.
The mechanical heat released
through the dehumidification proc
-
ess is returned to the room.
With correct use, the dehumidi
-
fier only uses about 25% of the
energy that would be needed for
the „heating and ventilation”
principle.
The relative humidity
Our ambient air is a gas mixture
and contains always a certain
amount of water in the form of
water vapour. This water volume is
expressed in g per kg dry air (abso
-
lute water content).
1m
3
air
weighs about 1,2 kg at 20 ° C
Depending on the temperature,
each kg of air is only able to ab-
sorb a certain amount of water va-
pour. When this absorptive capac
-
ity is reached, reference is made to
“saturated” air; this has a relative
humidity of (R H) 100%.
Relative humidity is therefore un
-
derstood to be the ratio between
the amount of water vapour cur-
rently contained in the air and the
maximum water vapour volume at
the same temperature.
The ability of air to absorb water
vapour increases with increas
-
ing temperature. This means that
the maximum (= absolute) water
content increases with increasing
temperature.
4
REMKO AMT
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for REMKO AMT 80E at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of REMKO AMT 80E in the language / languages: English as an attachment in your email.

The manual is 1,53 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of REMKO AMT 80E

REMKO AMT 80E User Manual - German - 24 pages

REMKO AMT 80E User Manual - Dutch - 24 pages

REMKO AMT 80E User Manual - French - 24 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info