11.7 Appoint en eau de l'installation de chauffage
Important
La pression hydraulique recommandée se situe entre 1,5 bar et
2 bar.
Ouvrir les robinets de tous les radiateurs de l'installation de
chauffage.
11.7.1 Appoint manuel en eau de l'installation de chauffage
Si l'installation de chauffage est vide ou si la pression hydraulique est trop
basse, remplir l'installation de chauffage. Pour ce faire, procéder comme
suit :
1. Vérifier la pression hydraulique du système de chauffage central
indiquée sur l'afficheur du tableau de commande. Au besoin, faire
l'appoint en eau de l'installation de chauffage central.
2. Ouvrir les robinets de tous les radiateurs de l'installation de chauffage.
3. Régler le thermostat d'ambiance sur la température la plus basse
possible.
4. Surveiller le remplissage de l'installation jusqu'à ce que les radiateurs
ouverts soient tièdes ou plus froids.
5. Pour le remplissage, utiliser un flexible de remplissage équipé de
deux raccords pour robinet, un chiffon et une clé de purge.
6. Connecter le flexible de remplissage à un robinet d'eau froide.
7. Éliminer l'air du flexible de remplissage. Remplir doucement le flexible
d'eau. Maintenir l'extrémité du flexible au-dessus d'un récipient.
Fermer le robinet dès que l'eau sort du flexible.
Fig.83 Remplir le système
AD-3001242-01
4
3
1
2
3
4
2
Fig.84 Remplir le système
AD-3001243-01
7
6
5
11 Instructions pour l'utilisateur
7680255 - v.02 - 21112018 67
67


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Remeha Tzerra Ace 35C Plus at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Remeha Tzerra Ace 35C Plus in the language / languages: French as an attachment in your email.

The manual is 3.16 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Remeha Tzerra Ace 35C Plus

Remeha Tzerra Ace 35C Plus Usermanual and installation guide - Dutch - 84 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info