9.1 Sensors and measuring instruments
Temperature sensors
The product range includes high-precision platinum temperature sensors, atscrew
sensors, outdoor temperature sensors, indoor temperature sensors, cylindrical clip-
on sensors, also as complete sensors with immersion sleeve.
Order information can be found in our catalogue and on our Web site.
SP10 Overvoltage protection device
In order to avoid overvoltage damage at collector sensors (e.g. caused by local light-
ning storms), we recommend installing the overvoltage protection SP10.
9.2 VBus® accessories
SD3 Smart Display
The Smart Display is designed for simple connection to controllers with VBus®. It
is used for visualising data issued by the controller: collector temperature, store
temperature and energy yield of the solar thermal system. The use of high-efciency
LEDs and lter glass assures a high optical brilliance. An additional power supply is
not required.
GA3 Large display module
The GA3 is a completely mounted large display module for visualisation of collec-
tor- and store temperatures as well as the heat quantity yield of the solar system via
one 6-digit and two 4-digit 7-segment-displays. An easy connection to all controllers
with VBus® is possible. The front plate is made of antireective lterglass and is
printed with a light-resistant UV-lacquering. The universal VBus® allows the parallel
connection of 8 large displays as well as additional VBus® modules.
AM1 Alarm Module
The AM1 Alarm Module is designed to signal system failures. It is to be connected
to the VBus® of the controller and issues an optical signal via the red LED if a failure
has occurred. The AM1 also has a relay output, which can e. g. be connected to a
building management system (BMS). Thus, a collective error message can be issued
in the case of a system failure.
The AM1 Alarm module ensures that occurring failures can be immediately recog-
nised and repaired, even if the system and the controller are difcult to access or
located in a remote place. Thus, the reliability and the stable yield of the system are
ensured.
DL2 Datalogger
This additional module enables the acquisition and storage of large amounts of data
(such as measuring and balance values of the solar system) over a long period of
time. The DL2 can be congured and read-out with a standard Internet browser
via its integrated web interface. For transmission of the data stored in the internal
memory of the DL2 to a PC, an SD card can be used. The DL2 is appropriate for all
controllers with VBus®. It can be connected directly to a PC or router for remote
access and thus enables comfortable system monitoring for yield monitoring or for
diagnostics of faults.
DL3 Datalogger
Be it solar thermal, heating or DHW heat exchange controllers – with the DL3 you
can easily and conveniently log system data of up to 6 controllers. Get a comprehen-
sive overview of all controllers connected with the large full graphic display. Transfer
data with an SD memory card, or use the LAN interface to view and process data
on your PC.
9.3 Interface adapters
VBus® / USB interface adapter
The VBus® / USB interface adapter is the interface between the controller and a
personal computer. With its standard mini USB port it enables a fast transmission of
system data for processing, visualising and archiving as well as the parametrisation of
the controller via the VBus®. The ServiceCenter software is included.
VBus® / LAN interface adapter
The VBus® / LAN interface adapter is designed for the direct connection of the
controller to a PC or router. It enables easy access to the controller via the local
network of the owner. Thus, controller access, system parameterisation and data
charting can be effected from every workstation of the network. The VBus® / LAN
interface adapter is suitable for all controllers equipped with a VBus®. The Ser-
viceCenter software is included.
70


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Remeha Sol Plus at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Remeha Sol Plus in the language / languages: English as an attachment in your email.

The manual is 3.79 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Remeha Sol Plus

Remeha Sol Plus User Manual - German - 72 pages

Remeha Sol Plus User Manual - Dutch - 72 pages

Remeha Sol Plus User Manual - French - 72 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info