Installation Indications, functions and options MessagesCommissioningOperation and function
Time period – switch-on condition
tDTO
Time period – switch-on condition
Adjustment range: 1 … 100 s
Factory setting: 60 s
The parameter tDTO is used for adjusting the time period during which the
switch-on condition must be permanently fullled.
Filling time
tFLL
Filling time
Adjustment range: 1.0 30.0 min
Factory setting: 5.0 min
The parameter tFLL is used for adjusting the lling time. During this period, the
pump runs at 100 % speed.
Stabilisation
tSTB
Stabilisation
Adjustment range: 1.0 15.0 min
Factory setting: 2.0 min
The parameter tSTB is used for adjusting the time period during which the switch-
off condition will be ignored after the lling time has ended.
Booster function
OBST option
Booster function
Adjustment range: ON / OFF
Factory setting: OFF
This function is used for switching on a second pump when lling the solar system.
When solar loading starts, R2 is energised in parallel to R1. After the lling time has
elapsed, R2 switches off.
Note
The booster function is available in system 1 only. The booster function will
only be available if the drainback option has been activated.
Operating mode
MAN1 / MAN2
Operating mode
Adjustment range: OFF, Auto, On
Factory setting: Auto
For control and service work, the operating mode of the relays can be manually
adjusted. For this purpose, select the adjustment value MAN1 (for R1) or MAN2
(for R2) in which the following adjustments can be made:
MAN1 / MAN2
Operating mode
OFF : Relay off (ashing) +
Auto : Relay in automatic operation
ON : Relay on (ashing) + + /
Note
Always adjust the operating mode back to Auto when the control and
service work is completed. Normal operation is not possible in manual
mode.
64


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Remeha Sol Plus at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Remeha Sol Plus in the language / languages: English as an attachment in your email.

The manual is 3.79 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Remeha Sol Plus

Remeha Sol Plus User Manual - German - 72 pages

Remeha Sol Plus User Manual - Dutch - 72 pages

Remeha Sol Plus User Manual - French - 72 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info