InstallationIndications, functions and optionsMessages Commissioning Operation and function
System cooling
OSYC
System cooling option
Adjustment range: OFF / ON
Factory setting: OFF
DTCO
Switch-on temperature difference
Adjustment range:
1.0 … 30.0 K [2.0 … 60.0 °Ra]
Factory setting: 20.0 K [40.0 °Ra]
The system cooling function aims to keep the solar system operational for a longer
time. The function overrides the maximum store temperature to provide thermal
relief of the collector eld and the heat transfer uid on hot days. If the store tem-
perature is higher than the adjusted maximum store temperature and the switch-
on temperature difference DTCO is reached, the solar pump remains switched
on or will be switched on. Solar loading is continued until either the temperature
difference falls below the adjusted value DTCF or the collector limit temperature
is reached. If the system cooling function is active, and are displayed (ashing).
DTCF
Switch-off temperature difference
Adjustment range: 0.5 … 29.5 K [1.0 … 59.0 °Ra]
Factory setting: 15.0 K [30.0 °Ra]
Note
This function will only be available, if the collector cooling function
(OCC) is deactivated.
Store cooling
OSTC
Store cooling option
Adjustment range: OFF / ON
Factory setting: OFF
OHOL
Holiday cooling option
Adjustment range: OFF / ON
Factory setting: OFF
THOL
Holiday cooling temperature
Adjustment range: 20 … 80 °C [70 … 175 °F]
Factory setting: 40 °C [110 °F]
When the store cooling function is activated, the controller aims to cool down the
store during the night in order to prepare it for solar loading on the following day.
If the adjusted maximum store temperature (S MX / S1MX) is exceeded and the
collector temperature falls below the store temperature, the system will be reacti-
vated in order to cool down the store. Cooling will continue until the store temper-
ature has fallen below the adjusted maximum store temperature (S MX / S1MX)
again. A hysteresis of 2 K [4 °Ra] is set for the store cooling function.
Reference threshold temperature differences for the store cooling function are
DT O and DT F.
If no DHW consumption is expected for a longer period of time, the additional
holiday cooling option OHOL can be activated in order to extend the store cool-
ing function. The adjustable temperature THOL then replaces the maximum store
temperature (S MX / S1MX) as the switch-off temperature for the store cooling
function.
When the holiday cooling function is activated, and (ashing) are shown on
the display.
If the holiday cooling function is active, , and are displayed (ashing).
59


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Remeha Sol Plus at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Remeha Sol Plus in the language / languages: English as an attachment in your email.

The manual is 3.79 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Remeha Sol Plus

Remeha Sol Plus User Manual - German - 72 pages

Remeha Sol Plus User Manual - Dutch - 72 pages

Remeha Sol Plus User Manual - French - 72 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info