Paramètre Description Plage de
réglage
Pas de
réglage
Réglage
d’usine
Remarques
CMIN Température minimale du
capteur
10 / 90 °C 0.5 30 ¼Voir chapitre : "Description des
paramètres installateur", page 52
OAC Option antigel des
capteurs
On / OFF OFF 4On : Activé
4OFF : Désactivé
¼Voir chapitre : "Description des
paramètres installateur", page 52
TAON Température d’activation
de la fonction antigel
-4 / 5.5 °C 0.5 4 Disponible si OAC = On
TAOF Température de
désactivation de la fonction
antigel
4.5 / 9 °C 0.5 6 Disponible si OAC = On
FT Option capteur tubulaire On / OFF OFF 4On : Activé
4OFF : Désactivé
¼Voir chapitre : "Description des
paramètres installateur", page 52
POMP Mode de commande de la
pompe
OnOF / PuLS /
PSOL
PSOL 4OnOF : Circulateur tout ou rien
(0% ou 100%)
4PuLS : Modulation de la pompe de
50% à 100%
4PSOL : Circulateur à commande
PWM solaire
PN Régime minimum de la
pompe solaire
20 / 100% 1 30
OTHR Activation de l’appoint
électrique
On / OFF OFF(1) 4On : Appoint électrique présent
4OFF : Pas d’appoint électrique
Si la sonde eau chaude sanitaire S3 est
raccordée, le réglage OFF n’est pas
disponible.
THRn Température de consigne
nocturne de l’appoint
40 / 95 °C 0.5 55 ¼Voir chapitre : "Description des
paramètres installateur", page 52
tn O Heure d’activation de
l’appoint en période
nocturne
00:00 / 23:45 00:15 23:00
tn F Heure de désactivation de
l’appoint en période
nocturne
00:00 / 23:45 00:15 07:00
O td Option appoint en période
diurne
On / OFF ON 4On : Activé
4OFF : Désactivé
¼Voir chapitre : "Description des
paramètres installateur", page 52
THRd Température de consigne
diurne de l’appoint
40 / 95 °C 0.5 55 ¼Voir chapitre : "Description des
paramètres installateur", page 52
td O Heure d’activation de
l’appoint en période diurne
00:00 / 23:45 00:15 16:00 Disponible si O td = On
td F Heure de désactivation du
thermostat diurne
00:00 / 23:45 00:15 18:00 Disponible si O td = On
DMAX Débit maximum (l/min) 0.5 / 100 10 - 1 - 0.1 3 ¼Voir chapitre : "Description des
paramètres installateur", page 52
GELT Type d’antigel 0 / 1 / 2 / 3 / 4 1 3 40 : Eau
41 : Glycol propylénique
42 : Glycol éthylénique
43 : Tyfocor LS / G-LS
44 : Greenway
(1) Le paramètre est réglé sur On si la sonde eau chaude sanitaire S3 est raccordée
200SE-2S - 300SE-2S 5. Mise en service
26/04/2016 - 7607572-07 51
53


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Remeha Remasol 200SE 2S at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Remeha Remasol 200SE 2S in the language / languages: French as an attachment in your email.

The manual is 6.55 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Remeha Remasol 200SE 2S

Remeha Remasol 200SE 2S Installation Guide - Dutch - 80 pages

Remeha Remasol 200SE 2S User Manual - Dutch - 28 pages

Remeha Remasol 200SE 2S User Manual - French - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info