689792
54
Zoom out
Zoom in
Previous page
1/88
Next page
9.4.7 Checking the non-return valve
1. Disconnect the two fan plugs on the front and rear.
2. Remove the screwed-on plug from the gas control valve.
3. Remove the ignition electrode plug from the ignition transformer.
4. Unscrew the nut of the gas valve unit.
5. Remove the air inlet pipe from the venturi.
6. Unscrew the two fan nuts.
7. Remove the fan together with the gas control valve.
8. Inspect the non-return valve and replace it in the event of a defect or
damage, or if the maintenance kit contains a non-return valve.
9. Reassemble in the reverse order.
Caution
Remember to reconnect the fan plugs.
Tighten the nut on the gas valve unit with a torque of 27.5 N⋅m.
Tighten the two fan nuts with a torque of 3.8 N⋅m.
9.5 Finalising work
1. Fit all removed parts in the reverse order, but do not close the casing
yet.
Caution
During inspection and maintenance operations, always replace all
gaskets on the parts removed.
2. Fill the siphon with water.
3. Put the siphon back in place.
4. Carefully open all system and supply valves which were closed to
carry out the maintenance.
5. Fill the central heating system with water if necessary.
6. Vent the central heating system.
7. Top up with more water if necessary.
8. Check the tightness of the gas and water connections.
9. Put the boiler back into operation.
10. Carry out an auto-detect when a control board has been replaced or
removed from the boiler.
11. Set the boiler to full load and carry out a gas leak detection and a
thorough visual check.
12. Set the boiler to normal operation.
Fig.64 Disconnecting the fan
AD-3001178-02
1
2
3
Fig.65 Removing the gas and air supply
pipes
AD-3001971-01
4
5
Fig.66 Checking the non-return valve
AD-3001181-02
2x
6
8
7
9 Maintenance
54 7684359 - v.11 - 13122021
54


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Remeha Quinta ACE 90 T-Control at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Remeha Quinta ACE 90 T-Control in the language / languages: English as an attachment in your email.

The manual is 4.19 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Remeha Quinta ACE 90 T-Control

Remeha Quinta ACE 90 T-Control Usermanual and installation guide - German - 116 pages

Remeha Quinta ACE 90 T-Control Usermanual and installation guide - Dutch - 80 pages

Remeha Quinta ACE 90 T-Control Usermanual and installation guide - French - 84 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info