Room-sealed model (C13, C33, C63, C93)
L Total length of the flue gas outlet and air supply duct
Connecting the flue gas outlet
Connecting the air supply
With a room-sealed version, both the flue gas outlet and the air supply
openings are connected (concentrically).
Tab.14 Maximum chimney length (L)
Diameter(1) 80/125 mm 100/150 mm
Quinta Ace 30 20 m 20 m(1)
Quinta Ace 45 20 m 20 m(1)
Quinta Ace 55 8 m 20 m(1)
Quinta Ace 65 4 m 18 m
Quinta Ace 90 4 m 17 m
Quinta Ace 115 - 13 m
(1) Retaining the maximum chimney length it is possible to use an extra 5 x 90º
or 10 x 45º elbows.
Connection in different pressure areas (C53)
LTotal length of the flue gas outlet and air supply duct
Connecting the flue gas outlet
Connecting the air supply
An 80/80 or 100/100 mm flue gas adapter (accessory) must be fitted for
this connection.
Combustion air supply and flue gas discharge are possible in different
pressure areas and semi-CLV systems, with the exception of the coastal
area. The maximum permitted height difference between the combustion
air supply and the flue gas outlet is 36 m.
Tab.15 Maximum length (L)
Diameter(1) 80 mm 90 mm 100 mm 110 mm 130 mm
Quinta Ace 30 17 m 29 m 40 m 40 m(1) 40 m(1)
Quinta Ace 45 29 m 40 m 40 m(1) 40 m(1) 40 m(1)
Quinta Ace 55 9 m 17 m 27 m 40 m 40 m(1)
Quinta Ace 65 5 m 10 m 16 m 34 m 40 m(1)
Quinta Ace 90 - - 17 m 37 m 40 m(1)
Quinta Ace 115 - - 14 m 31 m 40 m(1)
(1) Retaining the maximum chimney length it is possible to use an extra 5 x 90º or 10 x 45º elbows.
Reduction table
Tab.16 Pipe reduction for each bend - radius ½D (parallel)
Diameter 80 mm 100 mm
45° bend 1.2 m 1.4 m
90° bend 4.0 m 4.9 m
Fig.8 Room-sealed version (concentric)
AD-0000029-02
L =
Fig.9 Different pressure areas
AD-0000030-02
= L +
Fig.10 Bend radius ½D
AD-3001608-01
R=½D
D
4 Preparation of installation
7684359 - v.11 - 13122021 19
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Remeha Quinta Ace 55 - T-Control at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Remeha Quinta Ace 55 - T-Control in the language / languages: English as an attachment in your email.

The manual is 4.19 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info