805746
46
Zoom out
Zoom in
Previous page
1/88
Next page
Code Display text Description Adjustment range Subme
nu
30 45 55 65 90 115
DP070 DHW com
fort setpoint
Comfort temperature set
point for the Domestic Hot
Water tank
40 - 65 °C Internal
DHW
60 60 60 60 60 60
DP080 DHW re
duced set
point
Reduced temperature set
point from the Domestic
Hot Water tank
7 - 50 °C Internal
DHW
15 15 15 15 15 15
DP200 DHW mode DHW primary mode cur
rent working setting
0 = Scheduling
1 = Manual
2 = Off
Internal
DHW
1 1 1 1 1 1
DP337 DHW holi
day setpoint
Holiday temperature set
point from the Domestic
Hot Water tank
10 - 60 °C Internal
DHW
10 10 10 10 10 10
Tab.44 Navigation for installer level
Level Menu path
Installer > Installation Setup > CU-GH08 > Submenu (1) > Parameters, counters, signals > Parameters >
General
(1) See the column "Submenu" in the following table for the correct navigation. The parameters are grouped in specific functionalities.
Tab.45 Factory settings at installer level
Code Display text Description Adjustment range Subme
nu
30 45 55 65 90 115
AP001 BL function BL input function selection 1 = Full blocking
2 = Partial blocking
3 = User reset lock
ing
Gas
fired ap
pliance
1 1 1 1 1 1
AP003 Flue valve
wait time
Heat generator wait time
to open the flue gas
0 - 255 Sec Gas
fired ap
pliance
0 0 0 0 0 0
AP006 Min. water
pressure
Appliance will report low
water pressure below this
value
0 - 6 bar Gas
fired ap
pliance
0.8 0.8 0.8 0.8 0.8 0.8
AP008 Release
wait time
Waiting time after closing
the release contact to start
the heat generator.
0 - 255 Sec Gas
fired ap
pliance
0 0 0 0 0 0
AP009 Service
hours
Number of heat generator
operating hours for raising
a service notification
0 - 51000 Hours Gas
fired ap
pliance
6000 6000 6000 6000 6000 6000
AP010 Service noti
fication
Select the type of service
notification
0 = None
1 = Custom notifi
cation
2 = ABC notifica
tion
Gas
fired ap
pliance
2 2 2 2 2 2
AP011 Service
hours mains
Hours powered to raise a
service notification
0 - 51000 Hours Gas
fired ap
pliance
3500
0
3500
0
3500
0
3500
0
3500
0
3500
0
AP013 Release
function
Function of the release in
put contact
0 = Disabled
1 = Full blocking
2 = Central heat
blocked
Gas
fired ap
pliance
1 1 1 1 1 1
AP018 Sets release
input
Configuration of the re
lease input contact (nor
mally open or normally
closed)
0 = Normally open
1 = Normally
closed
Gas
fired ap
pliance
0 0 0 0 0 0
AP079 Building In
ertia
Inertia of the building used
for heat up speed
0 - 15 Outdoor
tempera
ture
3 3 3 3 3 3
8 Settings
46 7684359 - v.11 - 13122021
46


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Remeha Quinta Ace 30 - T-Control at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Remeha Quinta Ace 30 - T-Control in the language / languages: English as an attachment in your email.

The manual is 4.19 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info