0! Short circuit
24V
Check wiring.
0@
No flame or no
ionisation (after
5 start attemps)
Note:
Ionisation
measurement
in Volts
between
terminal 4 and
earth
(1V dc
1µ A dc)
No ignition spark, check:
- connection of ignition cable and spark plug cap
- ignition cable and electrode for insulation breakdown
- electrode gap; must be 3-4 mm
- earth continuity
Ignition spark, but no flame, check if:
- gas cock is open
- inlet gas pressure is sufficient
- gas pipe is vented (special attention for LPG use)
- gas valve is energised during ignition and also opens
- electrode is fitted properly, is clean and set
- the gas/air ratio is correct (see Par. 9.1)
- the gas pipe is not clogged or incorrectly sized
- the air supply and flue outlet is free of obstructions
- if the condensate siphon is clear
- there is no flue gas recirculation (internal/external)
Flame, but no or insufficient (<5µA) ionisation. Check:
- earth continuity
- if the right electrode is fitted
- one of the temperature sensors is failing or poor
electrical connection (loss of current)
0$
Voltage failure after lock out condition – original lock out
cause will not be displayed – check read out table for
additional fault code, ref. Par. 6.9
0%
External
influence
- power or control supply affected by external EMC
check for EMC conformity
0* Setting failure
- check parameter D (second digit must be 0)
1! Failure of
internal
communication
bus
- short circuit in flat cable: replace flat cable
- water/condensation on display
- possibly external EMC contamination
54


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Remeha Quinta 45 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Remeha Quinta 45 in the language / languages: English as an attachment in your email.

The manual is 0,93 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Remeha Quinta 45

Remeha Quinta 45 Manual - Dutch - 2 pages

Remeha Quinta 45 User Manual - Dutch - 76 pages

Remeha Quinta 45 User Manual - Dutch - 76 pages

Remeha Quinta 45 User Manual - Dutch - 1 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info