689700
94
Zoom out
Zoom in
Previous page
1/136
Next page
9.4.1 TELLER, TIJDS PROG, KLOK \CNT menu's
Tab.66 Menu kiezen
Tellers Selectie
Circuit A tellers Kies het EHC-04 menu
Circuit B tellers Kies het SCB04-B menu
Tellers aangesloten op de werking
van de warmtepomp
Kies het EHC-04 menu
Tab.67 Beschikbare tellers
Parameter Beschrijving Eenheid EHC-04 SCB04-B
AC001 Aantal uren dat het toestel op netspanning was
aangesloten
uur X X
AC005 Energieverbruik voor centrale verwarming in kWh kWh X
AC006 Energieverbruik voor warmwater in kWh Wh X
AC007 Energieverbruik voor koeling in kWh Wh X
AC008 Energielevering centrale verwarming kWh X
AC009 Energielevering sanitair warm water kWh X
AC010 Energielevering koeling kWh X
AC013 Seizoensgebonden COP X
AC026 Aantal pompuren uur X
AC027 Aantal pompstarts - X
AC028 Totale werktijd van de eerste back-up trap uur X
AC029 Totale werktijd van de tweede back-up trap uur X
AC030 Totaal aantal starts van de eerste back-up trap - X
AC031 Totaal aantal starts van de tweede back-up trap - X
DC002 Aantal driewegklep schakelingen - X
DC003 Aantal uren dat driewegklep in warmwater stand
staat
uur X
DC004 Aantal starts van de compressor tijdens de sani
tair-warmwaterproductie
X
DC005 Aantal startpogingen van de compressor X
PC002 Aantal startpogingen van de compressor - - X
PC003 Aantal bedrijfsuren van de compressor uur X
CODE Voer de installateurscode in om naar de volgende
parameters te gaan.
X
AC002 Aantal bedrijfsuren uur X
AC003 Aantal bedrijfsuren sinds het laatste onderhoud
aan het toestel
uur X
AC004 Aantal geslaagde branderstarts sinds het laatste
onderhoud
X
AC013 Seizoensprestatiecoëfficiënt X
SERVICE Servicemelding resetten
CLR: de tellers AC002, AC003, en AC004 worden
teruggezet op nul.
X
9 Instellingen
94 7705298 - v03 - 16102018
94


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Remeha Mercuria WPR-2-E4-8 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Remeha Mercuria WPR-2-E4-8 in the language / languages: Dutch as an attachment in your email.

The manual is 16,31 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Remeha Mercuria WPR-2-E4-8

Remeha Mercuria WPR-2-E4-8 User Manual - Dutch - 52 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info