Figure 9 – Inspection valve assembly
Assembly of removable part
LEGEND
A hold in place
B turn clockwise
Test for the absence of ammonia using a phenolphthalein test strip.8.
Mount the unit upper panel.9.
WARNING! DO NOT START THE APPLIANCE WITHOUT THE SAFETY VALVE.
4 NONCONDENSABLE OR NONABSORBABLE GASES
Indirect control of the presence of non-condensable or non-absorbable gas in the
hermetic circuit or internal corrosion phenomena
The presence of corrosion phenomena inside the hermetic circuit has immediate effect
that cause machine anomalies that can be easily recognised:
development of a large amount of non-condensable and non-absorbable gas, pro-1.
duced of the corrosion reaction, which causes an accumulation of these gases in
the generator and, consequently, immediate overheating of the generator. This is
caused by the interruption of the water-ammonia solution evaporation process.
production of rust which, detaching from the internal walls of the hermetic circuit, 2.
rapidly blocks the circulation of refrigerant fluid, thus blocking the orifices of the
restrictors. This situation leads to a lack of water-ammonia solution to be evapo-
rated in the generator and causes the same over-heating phenomenon.
In both cases, the over-heating of the generator makes the manual-rearm safety thermo-
stat intervene, which is installed on the wall of the generator.
As a consequence, if there are no generator thermostat interventions, all corrosion phe-
nomena can be excluded and no inspection or additional action is necessary.
The possibility that internal corrosion phenomena are in progress must be taken into
consideration only when a series of five (5) thermostat interventions are detected. In this
case, contact the Technical Assistance.
72


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Remeha Gas HP 35 A LT-HT at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Remeha Gas HP 35 A LT-HT in the language / languages: English as an attachment in your email.

The manual is 11.83 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info