805735
65
Zoom out
Zoom in
Previous page
1/92
Next page
Checking the air pressure differential switch – side
1. Disconnect the short, dark-coloured silicon hose on the – side (P2) of
the air pressure differential switch.
2. Connect the – side of the air pressure differential switch to one end of
the T piece with a hose.
3. Pull out the syringe until the boiler goes into failure mode.
4. Make a note of the pressure indicated by the pressure gauge at that
point.
A switch pressure of between - 5.5 and - 6.5 mbar is fine. A lower or
higher switch pressure indicates a problem with the air pressure
differential switch.
5. After taking a measurement, detach the silicon hose from the T-piece
on the – side and reconnect the coloured hose that was previously
removed.
6. Remove any soiling from all connection points for hoses and the air
pressure differential switch.
7. Check the condition and tightness of the hoses of the air pressure
differential switch.
Replace the hoses if necessary.
Fig.84 – side of the air pressure differential
switch
AD-0001076-01
SLOW
3
X mbar
........ mbar
4
-5.5 mbar....-6,5
(+)
P1(+)
1
2
P2(-)
10 Maintenance
7665063 - v.05 - 18102018 65
65


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Remeha Gas 220 Ace at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Remeha Gas 220 Ace in the language / languages: English as an attachment in your email.

The manual is 9.39 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Remeha Gas 220 Ace

Remeha Gas 220 Ace Usermanual and installation guide - German - 88 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info