Gas 210 Ace 80 120 160 200
Fuse – CU-GH13 (AT) 1.6 1.6 1.6 1.6
Fuse – CB-01 (AT) 6.3 6.3 6.3 6.3
(1) Without pump.
(2) For a room-sealed system.
Tab.66 Other data
Gas 210 Ace 80 120 160 200
Total weight with packaging Including control box kg 134 154 184 207
Total weight without packaging Including control box kg 115 135 165 188
Average acoustic level at a dis
tance of 1 metre from the boiler(1)
LpA dB(A) 59 59 59 59
Average acoustic level(1) LwA dB(A) 67 67 67 67
Ambient temperature °C max 40 40 40 40
(1) For a sealed installation.
Tab.67 Technical parameters
Gas 210 Ace 80 120 160 200
Condensing boiler Yes Yes Yes Yes
Low-temperature boiler(1) Yes Yes Yes Yes
B1 boiler No No No No
Cogeneration space heater No No No No
Combination heater No No No No
Rated heat output
Prated
kW 87 115 166 200
Useful heat output at nominal heat output and high
temperature operation(2)
P4
kW 87.0 115.0 166.0 200.0
Useful heat output at 30% of rated heat output and
low temperature regime(1)
P1
kW 29.1 37.7 55.2 66.6
Seasonal space heating energy efficiency
ƞs
%----
Useful efficiency at rated heat output and high temper
ature regime(2)
ƞ4
% 87.7 87.8 87.8 87.8
Useful efficiency at 30% of rated heat output and low
temperature regime(1)
ƞ1
% 97.7 97.5 97.3 97.6
Auxiliary electricity consumption
Full load
elmax
kW 0.103 0.167 0.196 0.306
Part load
elmin
kW 0.026 0.028 0.046 0.048
Standby mode
PSB
kW 0.006 0.006 0.006 0.006
Other items
Standby heat loss
Pstby
kW - - - -
Ignition burner power consumption
Pign
kW - - - -
Annual energy consumption
QHE
kWh
GJ
----
Sound power level, indoors
LWA
dB 67 67 67 67
Emissions of nitrogen oxides NOXmg/kWh 56 49 44 52
(1) Low temperature means 30 °C for condensing boilers, 37 °C for low temperature boilers and 50 °C (at heater inlet) for other heating
appliances.
(2) High temperature operation means 60 °C return temperature at heater inlet and 80 °C feed temperature at heater outlet.
See
Refer to the back cover for contact details.
12 Technical specifications
7837114 - v.01 - 10012023 81
81


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Remeha Gas 210 Ace at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Remeha Gas 210 Ace in the language / languages: English as an attachment in your email.

The manual is 6.15 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info