7.2.4 Servicing the forced flue connection pipes
1. Open the inspection hatches or remove the pipes.
2. Check that the air supply and discharge pipes are not blocked.
If necessary, clean the discharge pipe
3. Check the tightness of the flue gas system.
4. Replace the gaskets and, if necessary, any sections of pipe until the leak-tightness is perfect.
7.2.5 Checking the burner and cleaning the heat exchanger
1. Disconnect the two fan plugs on the front and rear.
2. Remove the screwed-on plug from the gas control valve.
3. Remove the ignition electrode plug from the ignition transformer.
4. Unscrew the nut of the gas valve unit.
5. Remove the air inlet pipe from the venturi.
6. Unscrew the front plate nuts.
7. Carefully lift the front plate, including the burner and fan, away from
the heat exchanger.
Fig.35 Disconnecting the fan
AD-3001178-02
1
2
3
Fig.36 Removing the gas and air supply
pipes
AD-3001971-01
4
5
Fig.37 Removing the front plate, fan and
burner
AD-3001179-01
6
7
7 Maintenance
36 Gas 120 ACE 7717202 - v04 - 23012023
36


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Remeha Gas 120 ACE at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Remeha Gas 120 ACE in the language / languages: English as an attachment in your email.

The manual is 5.01 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Remeha Gas 120 ACE

Remeha Gas 120 ACE Usermanual and installation guide - German - 64 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info