Tab.12 Paramètres techniques applicables aux dispositifs de chauffage mixtes par pompe à chaleur (paramètres déclarés
pour application à moyenne température)
Nom du produit WPR-2 V200
AWHP 8 MR-2
WPR-2 V200
AWHP 11 MR-2
AWHP 11 TR-2
WPR-2 V200
AWHP 16 MR-2
AWHP 16 TR-2
Pompe à chaleur air-eau Oui Oui Oui
Pompe à chaleur eau-eau Non Non Non
Pompe à chaleur eau glycolée-eau Non Non Non
Pompe à chaleur basse température Non Non Non
Équipée d’un dispositif de chauffage d’appoint Oui Oui Oui
Dispositif de chauffage mixte par pompe à chaleur Oui Oui Oui
Puissance thermique nominale dans des conditions
moyennes(1)
Prated
kW 6 6 9
Puissance thermique nominale dans des conditions
plus froides
Prated
kW 6 4 7
Puissance thermique nominale dans des conditions
plus chaudes
Prated
kW 6 8 13
Puissance calorifique déclarée à charge partielle
pour une température intérieure de 20 °C et une
température extérieure
Tj
Tj
= -7 °C
Pdh
kW 5,6 5,9 9,0
Tj
= +2 °C
Pdh
kW 2,9 5,3 6,5
Tj
= +7 °C
Pdh
kW 6,4 9,0 12,9
Tj
= +12 °C
Pdh
kW 4,3 7,7 10,0
Tj
= température bivalente
Pdh
kW 5,2 6,3 8,8
Tj
= température limite de fonctionnement
Pdh
kW 5,2 6,3 8,8
Température bivalente
Tbiv
°C -10 -10 -10
Coefficient de dégradation(2)
Cdh
1,0 1,0 1,0
Efficacité énergétique saisonnière pour le chauffa
ge des locaux dans des conditions moyennes
ƞs
% 129 125 121
Efficacité énergétique saisonnière pour le chauffa
ge des locaux dans des conditions plus froides
ƞs
% 119 113 113
Efficacité énergétique saisonnière pour le chauffa
ge des locaux dans des conditions plus chaudes
ƞs
% 169 167 161
Coefficient de performance déclaré ou coefficient
sur énergie primaire déclaré à charge partielle pour
une température intérieure de 20 °C et une tempé
rature extérieure
Tj
Tj
= -7 °C
COPd
- 1,95 1,87 1,85
Tj
= +2 °C
COPd
- 3,22 3,17 3,02
Tj
= +7 °C
COPd
- 4,57 4,54 4,34
Tj
= +12 °C
COPd
- 6,55 6,19 5,75
Tj
= température bivalente
COPd
- 1,70 1,20 1,35
Tj
= température limite de fonctionnement
COPd
- 1,70 1,20 1,35
Température limite de fonctionnement pour les
pompes à chaleur air-eau
TOL
°C -10 -10 -10
3 Caractéristiques techniques
20 7682781 - v02 - 09012018
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Remeha Eria Tower WPR-2-H V200 11-16 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Remeha Eria Tower WPR-2-H V200 11-16 in the language / languages: French as an attachment in your email.

The manual is 19.54 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Remeha Eria Tower WPR-2-H V200 11-16

Remeha Eria Tower WPR-2-H V200 11-16 Installation Guide - Dutch - 140 pages

Remeha Eria Tower WPR-2-H V200 11-16 User Manual - Dutch - 64 pages

Remeha Eria Tower WPR-2-H V200 11-16 User Manual - French - 64 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info