Type de gaz utilisé Paramètre Unité CALORA TOWER GAS
15Si BE
CALORA TOWER GAS
25Si BE
CALORA TOWER GAS
35Si BE
Gaz H (G20) MIN.VENT. tr/min 1800 1800 1700
MAX.VENT.CHAUF tr/min 4500 5200 5700
MAX.VENT.ECS tr/min 4500 5900 5700
VIT.DEM.VENT tr/min 3700 3700 4000
Gaz L (G25) MIN.VENT. tr/min 1800 1800 1700
MAX.VENT.CHAUF tr/min 4500 5200 5700
MAX.VENT.ECS tr/min 4500 5900 5700
VIT.DEM.VENT tr/min 3700 3700 4000
Propane (G31) MIN.VENT. tr/min 2200 1800 1700
MAX.VENT.CHAUF tr/min 4400 5300 6200
MAX.VENT.ECS tr/min 4400 5900 6200
VIT.DEM.VENT tr/min 3700 3000 4000
Tout type de gaz VIT.MAX POMPE % 60 60 60
Tout type de gaz VIT.MIN POMPE % 20 20 20
Niveau installateur - Menu #SECONDAIRE LIMITES
Paramètre Plage de réglage Description Réglage d’usine
MAX.CIRC.A 30 à 95 °C Température maximale (Circuit A)
¼ "MAX. CIRC. ...", page 99
75 °C
MAX.CIRC.B 20 à 95 °C Température maximale (Circuit B)
¼ "MAX. CIRC. ...", page 99
50 °C
MAX.CIRC.C 20 à 95 °C Température maximale (Circuit C)
¼ "MAX. CIRC. ...", page 99
50 °C
HORS GEL EXT. NON, -8 à +10 °C Température extérieure activant la protection hors-gel de
l’installation.
En-dessous de cette température, les pompes fonctionnent en
permanence et les températures minimales de chaque circuit sont
respectées.
En cas de réglage NUIT :ARRET, la température réduite de
chaque circuit est maintenue (Menu #SECONDAIRE P.INSTAL).
NON : La protection hors-gel n’est pas activée
+3 °C
TPC J A (1) (2) NON, 20 à 90 °C Température de pied de courbe en mode Jour (Circuit A) NON
TPC N A (1) (2) NON, 20 à 90 °C Température de pied de courbe en mode Nuit (Circuit A) NON
TPC J B (1) (2) NON, 20 à 90 °C Température de pied de courbe en mode Jour (Circuit B) NON
TPC N B (1) (2) NON, 20 à 90 °C Température de pied de courbe en mode Nuit (Circuit B) NON
TPC J C (1) (2) NON, 20 à 90 °C Température de pied de courbe en mode Jour (Circuit C) NON
TPC N C (1) (2) NON, 20 à 90 °C Température de pied de courbe en mode Nuit (Circuit C) NON
TEMP.PRIM.ECS (1) 50 à 95 °C Température de consigne chaudière en cas de production d’eau
chaude sanitaire
65 °C
(1) Le paramètre ne s’affiche que si le paramètre INSTALLATION est réglé sur ETENDUE
(2) Le paramètre peut être réglé sur la courbe de chauffe en appuyant sur la touche f.
CALORA TOWER GAS 15Si BE - 25Si BE - 35Si BE 6. Mise en service
15/03/2016 - 7605048-001-07 95
97


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Remeha Calora Tower Gas 15Si at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Remeha Calora Tower Gas 15Si in the language / languages: French as an attachment in your email.

The manual is 7.96 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Remeha Calora Tower Gas 15Si

Remeha Calora Tower Gas 15Si User Manual - German - 52 pages

Remeha Calora Tower Gas 15Si User Manual - Dutch - 44 pages

Remeha Calora Tower Gas 15Si Installation Guide - Dutch - 148 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info