3. Curves and Levels
Adjust image settings by moving Curve and Levels settings.
Comparison between before and after adjustment is displayed for
reference.
Example:
When the previewed image appears to be too dark, adjustments with the Input
slider in the Curves and Levels window can be made to correct the image. Selecting the Gray
slider in the center and moving it to the left will result in changes in the After” view resulting
in a lighter image. Once the adjusted image is acceptble select “OK” to send changes to
the scanning hardware. The same method can also be used to adjust each color channel
independently, using the channel drop down menu “RGB = All colors” R = Red, G = Green,
and B = Blue.
Menu Commands - Windows
Exposure Setting: To adjust the exposure time (R, G, B) press ”Reset” to restore
to the default setting.
Menu Commands - Help
Update Firmware: Upgrade the  rmware version, select the path where
the  le of  rmware has been saved. (These  les may be downloaded from
our website)
About: Display system information (including operation system, CPU),
product information (including product name, model name, hardware
version,  rmware version, software version, device information including
interface and optical resolution). This information is helpful to provide
when requesting technical support.
ENGLISH
29
ENGLISH
28
Default “Exposure Setting” is 100% for all 3 color channels.
Increase the exposure of the scanning light source if images are too
dark. Decrease exposure if images are too bright.
Menu Commands - Window (overview)
Settings for the CyberView window and Exposure adjustment for the scanner.
Menu Commands - Scan
a. Prescan
Prescan the existing  lm.
b. Scan
1. Scan Selected to File… > Scan the selected  lm to a speci ed path.
c. Revert
Discards all modi cations and restores the image back to the original
state.
Preference - See Scan Setting (See Page 13)
Exit
Closes the CyberView X5 user interface.
There is a message pop-up “Quit the application prompts to save docu-
ments?“ click “Yes“ to save , “No“ to discard the current
settings or “Cancel“ to return to Cyber View X.
1. Un/Lock scanning area.
2. Zoom In: Magnify image.
3. Zoom Out: Reduce image.
4. Rotate 90 Left: Turn the image 90° counter clockwise.
5. Rotate 90 Right: Turn the image 90° clockwise.
6. Flip Horizontal: Flip the image horizontally.
7. Flip Vertical: Flip the image vertically.
8. Revert: Discard all modi cations and restore the image.
Toolbar Diagram
II. Function Bar Diagram
In order to optimize scanned image quality, please select your  lm type and
brand from the toolbar:
Prescan:
Pre-scan the current  lm.
Scan: Scan  lm.
Image Adjustment: Press drop down button for more options.
Auto Calibrate: Calibrates the Scanner
32
32


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Reflecta CyberView X5 - MF5000 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Reflecta CyberView X5 - MF5000 in the language / languages: English as an attachment in your email.

The manual is 0,9 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Reflecta CyberView X5 - MF5000

Reflecta CyberView X5 - MF5000 User Manual - German - 36 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info