Safety instructions for installation
When placing items inside the unit, ensure that the steam can reach all surfaces and condensate can run o.
Never start the equipment without water and do not transport it during operation. Never add any liquid other than
drinking water to the container.
Add 180 ml tap water to the equipment. You can use the practical measuring cup included to do so. If you add
less than 180 ml of water, the steriliser unit does not produce sucient amounts of steam to disinfect all items with
certainty.
Caution! Always open and dismantle the bottles into individual parts to sterilise, otherwise the material may become
warped.
Do not touch the equipment while in operation. The surfaces of the equipment become very hot during operation
and may cause burns.
CAUTION! Hot surface.
Do not remove the cover during disinfection as the equipment contains boiling water. Beware steam escaping from
the vents in the cover. Never put a cloth or similar over the cover.
Never open the equipment before the process is completed, as the items are then not disinfected.
Pay attention when opening the disinfecting unit - hot steam escaping may cause burns.
Bottles and other items are very hot directly after a hot steam disinfection and should only be removed using the
bottle gripper that is included.
Use the disinfected parts immediately after removing them, as otherwise they will have to be disinfected again.
Some condensate always remains in the equipment. Pour the water out of the unit and dry all parts of the equip-
ment. Caution - this remaining liquid may also be hot.
The disinfecting unit requires about 15 minutes to cool down before it can be started again.
Attention: Press the on/o button again to pause the disinfection and drying process. The disinfection
and drying process will begin again when you press the button again.
Cleaning
For reasons of hygiene and in order to keep lime deposits to a minimum, we recommend cleaning the steriliser,
removable basket and cover with a cloth after every use and removing remaining water from the steam container.
Always disconnect it from the mains and ensure that the equipment is cold before cleaning it. Do not immerse
the unit in water. The removable basket, cover, measuring cup and baby bottle mount unit are dishwasher-safe.
Do not use any scouring pads, scouring agents or solvents for cleaning; they might damage the equipment and
its surfaces.
Please ensure that the lter on the product base is not dusty. Remove the lter occasionally and clean it by simple
rinse with clear water.
Descaling
Environmental protection
The disinfecting unit must be descaled regularly, at least every month (more frequently in areas with very hard
water) in order to guarantee proper functioning of the equipment. A heating plate that appears dierent from
the outside with lime deposits or burnt-in milk residue does not constitute grounds for complaint. The warranty
does not cover any damage occurring due to this. The heating plate of your disinfecting unit may be cleaned with
traditional descaling products based on citric acid, e.g. using a reer fast bio-decalcier sachet or normal diluted
vinegar. Repeat the process in case of stubborn lime deposits. Please do not use chemical additives during
operation or cleaning.
Troubleshooting
Please retain your receipt, the user manual and part number. Warranty claims or claims from promises of guarantee
must be processed by the dealer.
The technical specication, instructions and characteristics of the product described herein have been compiled
to the best of our knowledge and belief and are correct at the time of printing. Any instructions provided by
reer should be correct and authoritative. Nevertheless,reer does not accept liability for potential errors in this
document and reserves the right to make changes to the product design and/or specications without prior notice.
Reproduction and disclosure of information contained in this copyright-protected document, in any form or by
any means - graphical, electronic or mechanical by photocopying, recording on tape or storage in a data retrieval
system (even in part), require prior written consent from reer.
At the end of its life, this product must not be disposed of as normal domestic waste, but should be recy-
cled at a collection point for electrical appliances. Please see the relevant syMaterials can be recycled as
specied. An important contribution to the protection of the environment can be made by reusing the unit,
recycling its components or otherwise reusing old applian-
ces. Please contact your local council to nd out more about
an appropriate disposal centre.
problem possible cause action
Why does the disinfection process
take so little time
You may have added insucient
water to the equipment
Add exactly 180 ml tap water to the
equipment
Device cannot be switched on No power supply
Insert the mains plug again and press
the on/o button on the equipment
Bottles and accessories are very hot
after the disinfection and drying
process
Disinfection and drying process
at over 90°C
Allow the bottles and accessories to
cool down and use the bottle gripper
included
Disinfection unit and bottles are
covered in white ecks after disin-
fection and drying
Equipment is calcied The disinfection unit must be descaled
Steam escaping from below the
cover
Equipment was assembled
incorrectly
Improper positioning of bottles
and other items
Assemble equipment correctly
Distribute bottles and other items
in such a way that the cover closes
completely
GBGB
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Reer 36040 VapoDry at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Reer 36040 VapoDry in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Spanish as an attachment in your email.

The manual is 14,6 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info