98
Before rst use
Please rinse all parts to be disinfected before starting the process and remove any food residue.
The disinfection process lasts for about 10 minutes. The disinfecting unit switches o automatically once the disinfec-
tion process is completed. Please wait for 3 minutes before removing the cover so that the equipment can cool down.
1
2
5
3
6
4
7 8
75 ml
water
Safety instructions on use
When placing items inside the unit, ensure that the steam can reach all surfaces and condensate can run o.
Never start the equipment without water and do not transport it during operation. Never add any liquid other than
drinking water to the container.
Add 75 ml tap water to the equipment. Keep this amount as accurate as possible. If you add less than 75 ml of water,
the disinfecting unit does not produce sucient amounts of steam to disinfect all items with certainty. If you use
more than 75 ml of water, the process is unnecessarily prolonged.
Do not start the equipment without having placed the parts basket inside.
Do not touch the equipment while in operation. The surfaces of the equipment become very hot during operation
and may cause burns.
CAUTION! Hot surface!
HeatColour function: the steam outlet becomes bright red while hot steam is emerging.
Do not remove the cover during disinfection as the equipment contains boiling water. Beware steam escaping from
the vents in the cover. Please do not obstruct the opening or place a cloth over the cover.
Never open the equipment before the process is completed, as the items are then not disinfected.
Pay attention when opening the disinfecting unit - hot steam escaping may cause burns.
Bottles and other items are very hot directly after a hot steam disinfection and should only be removed using the
bottle gripper that is included.
Use the disinfected parts immediately after removing them, as otherwise they will have to be disinfected again.
Some condensate always remains in the equipment. Pour the water out of the unit and dry all parts of the equip-
ment. Caution - this remaining liquid may also be hot.
The disinfecting unit requires about 15 minutes to cool down before it can be started again.
Note: After the disinfection process has started, it can only be stopped by disconnecting the power supply.
Cleaning
For reasons of hygiene and in order to keep lime deposits to a minimum, we recommend cleaning the disinfecting
unit, bottle basket and cover with a cloth after every use. Always disconnect it from the mains and ensure that the
equipment is cold before cleaning it. Do not immerse the unit in water. The bottle grid and small parts basket are
dishwasher-safe. Do not use any scouring pads, scouring agents or solvents for cleaning; they might damage the
equipment and its surfaces. If the equipment is not cleaned and dried after every use, lime deposits will occur on
the heating plate at the bottom of the disinfecting unit after some time.
GB
GB
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Reer 36010 VapoMax at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Reer 36010 VapoMax in the language / languages: English, German, Dutch, French, Italian, Polish, Spanish as an attachment in your email.

The manual is 6,79 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info