CURING/DRYING PROCESS CONTROL
In a typical manufacturing curing/drying process, it is required to control the
duration of time heat is applied to the items within an oven. These items are to
be heated at a high temperature for a long period of time (30 minutes). At the
end of the curing/drying process, the heat is turned off and an indicator light is
turned on, signaling the unloading attendant. The dual preset Libra timer will
satisfy all these requirements.
The Libra timer is first set to minutes time range, which is time range 9. Next,
the mode switches are set to Mode 0 (Latch Outputs at Presets, Manual Reset to
Zero, Time Stops at Preset 2). Mode 0 is used because the outputs must latch on
when the presets are reached (When the outputs latch on, the heaters de-
energize). Also, the time increments will stop at preset 2. The power-up reset
switch is set to “Enable”, which causes the unit to start the cycle over in the
event of an input power loss (when enabled, the unit will reset itself when input
power is restored). The front panel reset button “EN./DIS.” switch is “Disabled”
to prevent accidental resetting (restarting) of the cycle. The “REM. RST.”
terminal is connected to a remote reset button located at the loading end of the
oven. The “PGM. DIS.” and the “RUN” terminals are tied to the “COMMON”
terminal. With “PGM. DIS.” tied low (this is done after preset 1 is set to 3
minutes and preset 2 is set to 33 minutes), the heating time periods cannot be
changed. “RUN” is permanently tied low, which causes the unit to increment
time (when Preset 2 is reached, Mode 0 will cause time accumulation to stop).
The normally closed contact of Relay 1 is connected to the high temperature
heater and the normally closed contact of Relay 2 is connected to the low
temperature heater. The operation sequence is as follows:
The operator/attendant wheels a rack of items into the heating area (oven).
Once the oven doors are closed, the operator/attendant presses the remote reset
switch which starts the heating cycle (both high and low temperature heaters are
turned on at this time). After three minutes have elapsed, output 1 fires, which
opens the normally closed contact of Relay 1. (This turns off the high
temperature heater.) After 30 minutes have elapsed, output 2 fires, which stops
the time accumulation and opens the normally closed contact of Relay 2. (This
turns off the low temperature heater.) Also, the normally open contact of Relay
2 closes, which then turns on the indicator light. (This signals the unloading
attendant that the process is complete.)
ORDERING INFORMATION
APPLICATION FOR DUAL LEVEL PRESET LIBRA TIMER
INSTALLATION
The Libra counters and timers are designed to be panel-mounted with a
gasket to provide a water-tight seal. Two mounting clips and screws are
provided for easy installation. Consideration should be given to the thickness
of the panel. Too thin of a panel may distort and not provide a water-tight seal.
(Recommended minimum panel thickness is 1/8".)
After the panel cut-out has been completed and deburred, carefully apply
the gasket to the panel. DO NOT APPLY THE ADHESIVE SIDE OF THE
GASKET TO THE COUNTER BEZEL. Insert the unit into the panel. As
depicted in the drawing (at right), install the screws into the narrow end of the
mounting clips. Thread the screws into the clips until the pointed end just
protrudes through the other side. Install each of the two mounting clips by
inserting the wide lip of the clips
into the front end of the hole,
located on either side of the case.
Then snap the clip onto the case.
Tighten the screws evenly to
apply uniform compression, thus
providing a water-tight seal.
Caution: Only minimum pressure
is required to seal panel. Do NOT
over-tighten mounting screws.
MODEL NO. DESCRIPTION
230 VAC 115 VAC
LIBT1 Single Preset LCD Libra Timer LIBT1010 LIBT1000
LIBT2 Dual Preset LCD Libra Timer LIBT2010 LIBT2000
LIBT1E Single Preset LED Libra Timer LIBT1E10 LIBT1E00
For more information on Pricing, Enclosures & Panel Mount Kits refer to the RLC Catalog or contact
your local RLC distributor.
LIBT2E Dual Preset LED Libra Timer LIBT2E10 LIBT2E00
PART NUMBERS FOR AVAILABLE
SUPPLY VOLTAGES
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Red Lion Libra Series Timers at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Red Lion Libra Series Timers in the language / languages: English as an attachment in your email.

The manual is 0.34 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info