597817
49
Zoom out
Zoom in
Previous page
1/250
Next page
RED EPIC OPERATION GUIDE
COPYRIGHT © 2013 RED.COM, INC
955-0002_v4.0, Rev-A | 49
ICON Behavior
CAL:T/E
T or E Green - No change in sensor temperature or exposure from the levels recorded during calibration
T or E Yellow - Slight change in sensor temperature or exposure from the levels recorded during calibration
T or E Red - Significant change in sensor temperature or exposure from the levels recorded during
calibration
The - and + indicate whether the sensor temperature or exposure has decreased or increased
NOTE: The T and E change colors independently of each other.
TC
TC Gray - No analog time code is currently detected
TC Red - Analog time code is being detected, but the use of it is not enabled
TC Green - Analog time code is being used to jam the time of day time code. TC will revert to gray if the
signal is no longer detected
GEN
GEN Gray - No genlock signal is currently detected, or the presented signal cannot crosslock to project
(24.00 fps vs. 23.98 fps)
GEN Red - During process of sync, or if genlock is lost while recording
GEN Green - A genlock signal matching the current HD-SDI monitor rate has been locked to it
GEN Yellow - When timing is cross-locking to compatible but not matching monitor rate. i.e. genlock =
24.00, HD-SDI monitor rate = 25.00
NOTE: 3D operation should not be done if GEN is yellow. This is a warning that genlock source settings and
camera settings are not aligned. Phasing of the sync between cameras cannot be guaranteed when GEN is
yellow.
SYNC
SYNC Gray - The sensor sync mode is not Genlock
SYNC Red - The sensor sync mode is Genlock, but it is not locked to any genlock signal, or genlock or
sensor sync is lost while recording
SYNC Green - A genlock signal compatible with the HD-SDI monitor rate has been locked to and the sensor
timing is also locked to it
POWER STATUS
If powering camera through DC power, the current voltage will be displayed. If using batteries, the remaining
battery time displays.
If using a REDBRICK or similar external battery to power the camera through DC IN, power status displays
49


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Red Epic - 4.0 2013 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Red Epic - 4.0 2013 in the language / languages: English as an attachment in your email.

The manual is 19,73 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info