656878
18
Zoom out
Zoom in
Previous page
1/18
Next page
18 CR Hydraulic Pump - Installation Guide
Set the speed control to achieve the desired hard-over to hard-over time
(nominally 12 seconds).
To adjust:
1. Loosen the locking nut using an 8mm spanner
2. Adjust the speed control using a flat-blade screwdriver. Screw in to reduce
speed.
3. Once the desired speed is achieved, tighten the locking nut
Maintenance
On a regular basis:
check all connections and mountings are secure
check pipes and cables for any signs of wear or damage
check hydraulic pipes and connections for leaks
Product support
Raymarine products are supported by a worldwide network of distributors and
Authorized Service Representatives. If you encounter any difficulties with this
product, please contact either your national distributor, service representative, or
the Raymarine Technical Services Call Center.
Contacting Raymarine in the US
You can contact Raymarine in the US using the previously detailed world wide
web or by calling one of the telephone numbers below:
1-800-539-5539, extension 2333, or
(603)- 881 - 5200
You can use these numbers Monday through Friday 0815 hrs to 1700 hrs Eastern
Standard Time or Eastern Daylight Savings Time.
Contacting Raymarine in Europe
You can obtain technical support, service and accessories from your authorized
Raymarine dealer, or by contacting:
Tel: +44 (0)23 9271 4713
Fax: +44 (0)23 9269 4642
87039_2.fm Page 18 Wednesday, April 9, 2014 2:56 PM
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Raymarine M81128 Constant Running Hydraulic Pump at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Raymarine M81128 Constant Running Hydraulic Pump in the language / languages: English as an attachment in your email.

The manual is 0,53 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info