5.1 General cabling guidance
Cable types and length
It is important to use cables of the appropriate type
and length
Unless otherwise stated use only standard cables
of the correct type, supplied by Raymarine.
Ensure that any non-Raymarine cables are of the
correct quality and gauge. For example, longer
power cable runs may require larger wire gauges
to minimize voltage drop along the run.
Routing cables
Cables must be routed correctly, to maximize
performance and prolong cable life.
Do NOT bend cables excessively. Wherever
possible, ensure a minimum bend diameter of 200
mm (8 in) / minimum bend radius of 100 mm (4 in).
100 mm (4 in)
200 mm (8 in)
Protect all cables from physical damage and
exposure to heat. Use trunking or conduit where
possible. Do NOT run cables through bilges or
doorways, or close to moving or hot objects.
Secure cables in place using tie-wraps or lacing
twine. Coil any extra cable and tie it out of the way.
Where a cable passes through an exposed
bulkhead or deckhead, use a suitable watertight
feed-through.
Do NOT run cables near to engines or uorescent
lights.
Always route data cables as far away as possible
from:
other equipment and cables,
high current carrying ac and dc power lines,
antennae.
Strain relief
Ensure adequate strain relief is provided. Protect
connectors from strain and ensure they will not pull
out under extreme sea conditions.
Cable shielding
Ensure that the cable is properly shielded that the
cable shielding is intact (e.g. hasn’t been scraped off
by being squeezed through a tight area).
5.2 Cable connection
The display has a combined power and transducer
cable that is attached to the transducer.
00
0
(0.6)VM
D12 642 -1
1
2
5
4
3
3
1. Display rear panel connection.
2. Transducer with cable attached.
3. Drain wire (The drain wire is the wire with a
sheath).
4. Black wire (12 V dc negative).
5. Red wire (12 V dc positive).
Power distribution
Raymarine recommends that all power connections
are made via a distribution panel.
All equipment must be powered from a breaker or
switch, with appropriate circuit protection.
All equipment should be wired to individual
breakers if possible.
Warning: Power supply voltage
Connecting this product to a voltage
supply greater than the specied
maximum rating may cause permanent
damage to the unit. Refer to the Technical
specication section for voltage rating.
Warning: Product grounding
Before applying power to this product,
ensure it has been correctly grounded, in
accordance with the instructions in this
guide.
Grounding Dedicated drain wire
The power cable supplied with this product includes
a dedicated shield (drain) wire for connection to a
vessel's RF ground point.
It is important that an effective RF ground is
connected to the system. A single ground point
should be used for all equipment. The unit can be
grounded by connecting the shield (drain) wire of
the power cable to the vessel's RF ground point.
34
Dragony® 6/ Dragony® 7
34


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Raymarine Dragonfly at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Raymarine Dragonfly in the language / languages: English as an attachment in your email.

The manual is 11,67 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Raymarine Dragonfly

Raymarine Dragonfly User Manual - German - 96 pages

Raymarine Dragonfly User Manual - Dutch - 96 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info