Sharingabreaker
Wheremorethan1pieceofequipmentsharesa
breakeryoumustprovideprotectionfortheindividual
circuits.E.g.byconnectinganin-linefuseforeach
powercircuit.
D116 37-2
2
4 4
1
3
+
-
1
Positive(+)bar
2
Negative(-)bar
3
Circuitbreaker
4Fuse
Wherepossible,connectindividualitemsof
equipmenttoindividualcircuitbreakers.Wherethis
isnotpossible,useindividualin-linefusestoprovide
thenecessaryprotection.
Warning:Productgrounding
Beforeapplyingpowertothisproduct,
ensureithasbeencorrectlygrounded,in
accordancewiththeinstructionsprovided.
GroundingDedicateddrainwire
Thepowercablesuppliedwiththisproductincludes
adedicatedshield(drain)wireforconnectiontoa
vessel'sRFgroundpoint.
ItisimportantthataneffectiveRFgroundis
connectedtothesystem.Asinglegroundpoint
shouldbeusedforallequipment.Theunitcanbe
groundedbyconnectingtheshield(drain)wireof
thepowercabletothevessel'sRFgroundpoint.
OnvesselswithoutanRFgroundsystemtheshield
(drain)wireshouldbeconnecteddirectlytothe
negativebatteryterminal.
Thedcpowersystemshouldbeeither:
Negativegrounded,withthenegativebattery
terminalconnectedtothevessel'sground.
Floating,withneitherbatteryterminalconnected
tothevessel'sground
Warning:Positivegroundsystems
Donotconnectthisunittoasystemwhich
haspositivegrounding.
Groundingadditionaldedicateddrainwire
required(CP470only)
TheCP470requiresanadditionaldedicateddrain
wire.Thiswiresupplementsthedrainwire(shield)
thatispartoftheproduct’spowercable.
CP470sonarmoduleadditionalgrounding
connection
D13308-1
5
1
2
3
4
ItemDescription
1Nut
2
Springwasher
3Washer
4Additionaldrainwire
5
Productadditionalgroundpoint
Connectoneendoftheadditionaldrainwiretoyour
product.T olocatetheadditionalgroundingpointon
yourproduct,refertotheConnectionsillustrationin
thisdocument.
Connecttheotherendoftheadditionaldrainwire
tothesamepointasthepowercabledrainwire
(shield).Thiswillbeeitherthevessel'sRFground
point,oronvesselswithoutanRFgroundsystem,
thenegativebatteryterminal.
Thedcpowersystemshouldbeeither:
Negativegrounded,withthenegativebattery
terminalconnectedtothevessel'sground;or
Floating,withneitherbatteryterminalconnected
tothevessel'sground.
Ifseveralitemsrequiregrounding,theymayrst
beconnectedtoasinglelocalpoint(e.g.within
aswitchpanel),withthispointconnectedviaa
single,appropriately-ratedconductor,tothevessel’s
commonRFgroundpoint.
Implementation
Thepreferredminimumrequirementforthepathto
groundisviaaattinnedcopperbraid,witha30A
rating(1/4inch)orgreater.Ifthisisnotpossible,an
equivalentstrandedwireconductormaybeused,
ratedasfollows:
forrunsof<1m(3ft),use6mm
2
(#10AWG)or
greater.
forrunsof>1m(3ft),use8mm
2
(#8AWG)or
greater.
Cablesandconnections29
29


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Raymarine CP570 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Raymarine CP570 in the language / languages: English as an attachment in your email.

The manual is 6,46 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Raymarine CP570

Raymarine CP570 Installation Guide - German - 66 pages

Raymarine CP570 Installation Guide - Dutch - 66 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info