Cable Part number MFD variant
Straight power
and data cable
(supplied with a9x
and a12x)
R62379 All variants
excluding a6x and
a7x
Right angled
power and data
cable
R70029 All variants
excluding a6x and
a7x
Cable extension
Power cables can be extended if required. The
following restrictions apply to any extension to the
power cable:
Cable must be of a suitable gauge for the circuit
load.
Each unit should have its own dedicated power
cable wired back to the distribution panel.
Total length
(max) Supply voltage
Cable gauge
(AWG)
12 V 18
0–5 m (0–16.4 ft)
24 V 20
12 V 145–10 m
(16.4–32.8 ft)
24 V 18
12 V 1210–15 m
(32.8–49.2 ft)
24 V 16
12 V 1215–20 m
(49.2–65.5 ft)
24 V 14
Note: a6x and a7x MFDs are 12 V only products. NEVER
connect a 12 V only product to a 24 V system.
Sharing a breaker
Where more than 1 piece of equipment shares a
breaker you must provide protection for the individual
circuits. E.g. by connecting an in-line fuse for each
power circuit.
D11637-2
2
4 4
1
3
+
-
1
Positive (+) bar
2
Negative (-) bar
3
Circuit breaker
4 Fuse
Where possible, connect individual items of
equipment to individual circuit breakers. Where this
is not possible, use individual in-line fuses to provide
the necessary protection.
58 a Series / c Series / e Series
58


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Raymarine c Series at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Raymarine c Series in the language / languages: English as an attachment in your email.

The manual is 30,39 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Raymarine c Series

Raymarine c Series User Manual - German - 396 pages

Raymarine c Series User Manual - Dutch - 394 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info