adartroubleshooting
Noconnectioncanbemadetothescanner
P
ossible
CausesPossibleSolution
R
adarpowered
down
Ifthescannerproducthasshutdown,poweritupbyopeningtheRadarapp
andselectingthe
P
owericon.
AQuantumRadarwillshutdownafter30minutesifneitherawired(RayNet),
norawireless(Wi-Fi)connectioncanbemadetoaMFD.
R adarnot
transmitting
Select
TransmitfortherelevantRadarscannerfromtheRadarapp.
Missingor
incorrectWi-Fi
credentials
Ifusingawireless(Wi-Fi)connection,checkthatyouhaveenteredthecorrect
SSIDandpasscodeforyourR
adar.BoththeSSIDandpasscodeareprovided
ontheRadarscanner’spackaging,andarealsoshownontheserialnumber
labelontheundersideoftheproduct.
Damagedor
disconnected
P owercable/
RayNetcable
1.Checkthatthecableconnectorsarefullyinsertedandlockedinposition.
2.Checkthepowersupplycableandconnectorsforsignsofdamageor
corrosion,replaceifnecessary.
3.Withtheproductturnedon,tryflexingthecableneartothedisplayconnector
toseeifthiscausestheproducttore-boot/loosepower,replaceifnecessary.
4.Checkthevessel’sbatteryvoltage,theconditionofthebatteryterminals
andpowersupplycables,ensuringconnectionsaresecure,cleanandfree
fromcorrosion,replaceifnecessary.
5.Withtheproductunderload,usingamulti-meter,checkforhighvoltage
dropacrossallconnectors/fusesetc(thiscancausetheproducttoreset/turn
off),replaceifnecessary.
6.Checkconditionofrelevantbreakersandfuses,replaceifnecessary.If
thebreakerkeepstrippingorfuseskeepblowing,contactaRaymarine
authorizeddealerforassistance.
OpenArray
powerinOff
position
EnsureOpenArraypowerswitchisintheOnposition.
Software
mismatch
between
equipment
mayprevent
communication
EnsureallR
aymarineproductscontainthelatestavailablesoftware,checkthe
Raymarinewebsite:www.raymarine.com/softwareforsoftwarecompatibility.
Displayedbearingisdifferenttothetruebearing
P ossible
CausesPossibleSolution
Bearing
alignment
adjustment
required
CarryouttheBearingAlignmentprocedure .
R adarwillnotinitialize(Voltagecontrolmodule(VCM)stuckinsleepmode”
P ossible
CausesPossibleSolution
Intermittentor
poorpower
connection
CheckpowerconnectionatV
CM.(Voltageatinput=12/24V,Voltageatoutput
=40V)
150
150


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Raymarine Axiom 12 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Raymarine Axiom 12 in the language / languages: English as an attachment in your email.

The manual is 9,22 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Raymarine Axiom 12

Raymarine Axiom 12 Installation Guide - English - 90 pages

Raymarine Axiom 12 User Manual - English - 60 pages

Raymarine Axiom 12 Usermanual and installation guide - German - 110 pages

Raymarine Axiom 12 Usermanual and installation guide - Dutch - 108 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info