597723
25
Zoom out
Zoom in
Previous page
1/76
Next page
Pag.25
EN
11. DESCRIPTION OF ALARMS
Unscrew the protection cap and press the
button to reset the thermostat alarm.
By pressing the button P3 on the display. the alarm can be reset.
Try and repeat lighting after the cooling phase.
WARNING REASON SOLVING
PELLETS FINISHED
ALARM
• The pellet tank is empty • Check whether there are pellets in the tank
• The ratiomotor does not load
pellets.
• Empty the tank to check that no objects have fallen inside which could prevent the
correct functioning of the screw
• No pellet loading • Regulate the pellet setting
• If the problem continues, contact the area Technical Assistance Centre.
BLACK - OUT
• No electricity supply during working phase • Press the off button and repeat switching on the stove
• If the problem continues, contact the area Technical Assistance Centre.
NO IGNITION ALARM
• The pellet tank is empty. • Check if there are pellets inside the tank.
• Setting of pellets and of intake during ignition phase insufficient. • Contact local Technical Assistance Centre.
• The resistance for lighting is defective or not in position • Contact local Technical Assistance Centre.
ALARM LOW FLAME
• The pellet tank is empty. • Ceckis pellet is in the hopper
• Bad setting of pellet and air on ignition phase • Contact local Technical Assistance Centre.
ALARM FAN RPM
• The revolution of smoke fan lowering morenthe 15% of speed to fan
congestion • Contact local Technical Assistance Centre.
ALARM FAN BROKEN
• Smoke extractor encoder is not functioning or not correctly connected • Contact local Technical Assistance Centre.
• No electricity supply to smoke extractor • Contact local Technical Assistance Centre.
• The smoke extractor is blocked • Contact local Technical Assistance Centre.
DEPRESSION ALARM
• The combustion chamber is dirty • Follow the cleaning operations of the stove as per the instructions in the booklet
• The flue is blocked • Check that the flue is clear and clean
• The vacuum switch is malfunctioning • Contact local Technical Assistance Centre.
THERMAL ALARM WITH
RESET
• The thermostat with manual reset has intervened • Reset the thermostat pressing the button on the back of the stove (see Fig. below).
• The centrifugal fan is defective • Contact local Technical Assistance Centre.
• Combustion in the fire pot is not optimal
• Switch off the stove, clean the re pot and regulate combustion with the setting of the pellets.
• If the problem continues, contact the area Technical Assistance Centre.
ALARM SOVRATEMP FUMI
• Combustion in the fire pot is not optimal
• Switch off the stove, clean the re pot and regulate combustion with the setting of the pellets.
• The centrifugal fan is defective • Please contact the local Technical Assistance Centre
• If the problem continues, contact the area Technical Assistance Centre.
SMOKE SENSOR ALARM
The smoke sensor is malfunctioning • Please contact the local Technical Assistance Centre
The smoke sensor has been disconnected from the board • Please contact the local Technical Assistance Centre
• If the problem continues, contact the area Technical Assistance Centre.
ALARM
INSUFFICIENT
FLOW
• The door and the ashtray are not corectly closed • Check the devices are closed
• Bad combustion in the fire pot • Switch off the stove, clean the fire pot, the grid and set the combustion through the set
pellet/flow.
Presence of a foreign object inside the inlet air • Check for and remove unwanted object
• Please contact the local Technical Assistance Centre
ALARM SPORCO
DEBIMETRO
• The device who read the quantity of inlet air could be dirty and so not
read correctly • Please contact the local Technical Assistance Centre
ALARM GUASTO
DEBIMETRO
• The device could be disconnected or defect • Please contact the local Technical Assistance Centre
ALARM
FASE COCLEA
• The gear motor is not correctly connected • Please contact the local Technical Assistance Centre
ALARM
TRIAC COCLEA
•The device in the motherboard who gears the screw is defect • Please contact the local Technical Assistance Centre
25


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ravelli MONICA at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ravelli MONICA in the language / languages: English, German, Danish, French, Italian, Spanish as an attachment in your email.

The manual is 3,8 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info