PLEASE FOLLOW THE INSTRUCTIONS FOR CLEAN-
ING SHOWN BELOW CAREFULLY! FAILURE TO OB-
SERVE THEM MAY LEAD TO PROBLEMS IN THE FUNC-
TIONING OF THE STOVE.
10.1. Cleaning the surfaces
To clean the surfaces on the painted metal parts, use a wet cloth in
water or at the most, water and soap.
Important: the use of aggressive detergents or diluents can damage
the surfaces of the stove.
10.2. Cleaning the fire pot before and after each lighting
You must check that the fire pot, where the combustion takes place,
is clean and that no waste or residue blocks the holes, in order to
always guarantee excellent combustion of the stove, thus avoiding
possible overheating, which could causes changes in the colour of
the paint or flaking of the door. as well as failing to light the stove.
Clean basket with all the
holes clearly visible
Basket needing cleaning
with the holes blocked by ashes
Only a clean fire pot can guarantee that the pellet stove functions
without problems. During functioning. deposits may be formed, which
have to be immediately eliminated.
It is easy to see when the fire pot has to be cleaned! It only needs a
glimpse, each day, before switching on. For minor cleansing, it can
be left in the stove, but if the residue is difficult to remove, it has to be
extracted from its housing and the waste scraped out.
The residue of ash depends on the quality of pellets used.
Important: even with a new batch of pellets, although using the same
brand, there may be differences during combustion and therefore
they may dirty to a greater or lesser extent.
Correct cleaning, done on a daily basis, allows the stove to burn
optimally and to have a good yield, avoiding malfunctioning which in
the long term could require technical assistance to reset the stove.
10.3. Cleaning the FIREX 600
All Ravelli products have a combustion chamber made with FIREX
600, a material based on vermiculite, the result of research and
development by Ravelli. The main features of FIREX 600 are resistant
to heat, its lightness and excellent insulating capacities, improving
the combustion and performance of the stove.
During combustion, FIREX 600 turns white, due to an effect called
PYROLYSIS, making the flame clear and shining. If the combustion
is regulated in an optimal way, the FIREX 600 interior always remains
clean and white.
The condition of FIREX 600 is therefore a thermometer to
understand whether the combustion is good or not.
FIREX 600 LIGHT – EXCELLENT COMBUSTION
FIREX 600 DARK – POOR COMBUSTION
Firex 600 does not require special maintenance, it only has to be
dusted with a brush to remove the ash that is deposited during
combustion.
Abrasive sponges to clean to most resistant waste should not be
used as they could compromise the thickness of the FIREX600 panel,
creating critical points of breakage.
The tube of the vacuum cleaner should not be used in direct contact
with FIREX 600.
Wet cloths should not be used to clean FIREX 600.
FIREX 600 is resistant to heat but not to knocks; handle with care if
moved.
FIREX 600 may show a slight abrasion after a few hours of functioning,
this is perfectly normal as the flame creates microgrooves in the
panel without compromising it.
The duration of FIREX 600 depends only on how maintenance is
carried out.
The pellet stove is a generator of heat with a solid fuel and as
such requires servicing by qualified personnel at least once
a year at the start of the season. This maintenance has the
purpose of ascertaining and ensuring the perfect efficiency of
all the components.
We recommend you draw up an annual contract for maintenance
of the product with your installer/dealer.
11. GUARANTEE
11.1. Certificate of Guarantee
Ravelli thanks you for the confidence you have placed in it with the
purchase of one of our pellet stoves and invites the purchaser to:
examine the instructions for the installation, use and maintenance
of the stove.
examine the conditions of guarantee shown below.
The enclosed coupon must be filled in and stamped by the installer.
If this does not occur, the product will not be covered by the guar-
antee.
11.2. Conditions of guarantee
The limited guarantee covers defects of manufacturing materials, on
condition that the product has not been broken due to an incorrect
use, carelessness, wrong connections or errors of installation.
The following are not covered by guarantee:
vermiculite (Firex 600);
the glass of the door;
the fibre gaskets;
the painting;
the stainless steel combustion basket;
the resistance;
the cast majolica
any damage caused by inappropriate installation and/or handling of
the stove and/or shortcomings by the consumer.
The use of poor quality pellets or of any other material could damage
components of the stove causing the termination of their guarantee
and the annexed responsibility of the manufacturer.
The pellets which meet the requisites listed in the chapter on them
should be used.
All damage caused by transport are not acknowledged, therefore
please carefully check the goods on receipt, immediately advising
the dealer of any damage.
All the manufacturer’s guarantees are shown here and no complaint
may be made to the manufacturer according to any other guarantee,
report or request.
The guarantee coupon must be detached and sent to the following
address within eight days of purchase:
Ravelli srl - Via Kupfer 31 - 25036 Palazzolo s/O Brescia IT-
ALY
11.3. Information and problems
For any information or problems, please contact your dealer or
service centre, the only people who can meet any request you may
have problem, if necessary, who can intervene directly.
24


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ravelli 900 Camino Flat at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ravelli 900 Camino Flat in the language / languages: English, German, Danish, French, Italian, Spanish as an attachment in your email.

The manual is 10,04 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info