6. POSITIONING, ASSEMBLY AND INSTALLATION
6.1. Positioning the stove with floor support (Standard supply
for 900 Flat and 901 Ducted, optional for 700,650, 550, 500).
The positioning of the stove is decisive for successful even heating
of the room. Before deciding where to place the stove, the following
must be taken into account:
The stove must be installed on a floor with a sufficient carrying ca-
pacity. If the existing building does not meet this requisite, appropri-
ate measures must be taken (i.e. load distribution plate).
The combustion air cannot be obtained from a garage or from an
area without ventilation or exchange of air, but from a free or exter-
nal space.
The stove must not be installed in a bedroom.
Installation is better in a large and central room in the house to en-
sure maximum circulation of the heat.
Connection to the mains supply is recommended using an earth
socket (if the cable supplied is not long enough to reach the nearest
socket, use an extension flush with the ground).
IMPORTANT GENERAL RULES
1.
It is obligatory to create an initial vertical section of 1.5 mt min. to
guarantee the correct expulsion of smoke.
2.
The pipes must be connected to each other with the male connec-
tor turned downwards to guarantee the smoke and condensation
seal through the gasket.
3.
Horizontal sections must never be more than 3 metres long and
the slope must never be less than 3-5%.
4.
The smoke discharge pipe fitting MUST NOT BE CONNECTED to
a flue used by other generators (stoves, chimneys, boilers..) and
to air extraction systems (HOODS, BREATHER PIPES etc...).
5.
The use of draught adjustment/interruption valves is banned.
Where there is poor or excessive draught in the flue, variations
must be made to the stove’s operating parameters. Contact the
Ecoteck authorised technical assistance centre.
Installation in an existing ue:
This type of installation (see Fig. 9) does not require an insulated
flue, since part of the smoke duct has been mounted inside the home
and part of it inside an already existing flue.
Two 45° pipe fittings are fitted in the middle part of the discharge;
you are advised not to install two 90° elbows since ashes would soon
block the flow of smoke, causing problems for the stove’s draught.
(see Fig. 10).
N.B.: The flue for discharging smoke must be made in observ-
ance of UNI 9615-9731, UNI 10683 - EN1856-1 standards both
with regard to the measurements and the materials used for
construction. Dilapidated flues, built with unsuitable material
(asbestos cement, zinc-plated steel etc..), can jeopardise the
ALESSIA (650)
U .M.
Height mm 580
Width mm 665
Depth mm 676
Weight Kg 120
Diameter of smoke exhaust duct mm 80
Max. volume of heating m
3
243 (90m
2
)
Min.-max. calorific power Kw/h 2,5 - 11
Min.-max. hourly consumption of pellets Kg/h 0,5 - 2,3
Electrical power absorbed during operation W 110
Supply V - Hz 220 - 50
Tank capacity Kg 15
Min.-max. autonomy h 6,5 - 30
The data shown above are indicative and not binding. Ecoteck reserves the right to make any modifications for the purpose of
improving the performances of the product.
The data referring to hourly consumption and autonomy have been calculated considering a pellet yield of: 1 kg= 4,7 Kw/h.
ERIKA (550)
U .M.
Height mm 563
Width mm 560
Depth mm 664
Weight Kg 105
Diameter of smoke exhaust duct mm 80
Max. volume of heating m
3
243 (90m
2
)
Min.-max. calorific power Kw/h 2,5 - 11
Min.-max. hourly consumption of pellets Kg/h 0,5 - 2,3
Electrical power absorbed during operation W 110
Supply V - Hz 220 - 50
Tank capacity Kg 14
Min.-max. autonomy h 6 - 28
The data shown above are indicative and not binding. Ecoteck reserves the right to make any modifications for the purpose of
improving the performances of the product.
The data referring to hourly consumption and autonomy have been calculated considering a pellet yield of: 1 kg= 4,7 Kw/h.
FLAT STOVE (900)
U .M.
Height mm 587
Width mm 863,5
Depth mm 650
Weight Kg 150
Diameter of smoke exhaust duct mm 80
Max. volume of heating m
3
243 (90m
2
)
Min.-max. calorific power Kw/h 2,5 - 11
Min.-max. hourly consumption of pellets Kg/h 0,5 - 2,4
Electrical power absorbed during operation W 110
Supply V - Hz 220 - 50
Tank capacity Kg 17
Min.-max. autonomy h 6,8 - 34
The data shown above are indicative and not binding. Ecoteck reserves the right to make any modifications for the purpose of
improving the performances of the product.
The data referring to hourly consumption and autonomy have been calculated considering a pellet yield of: 1 kg= 4,7 Kw/h.
DUCTED STOVE (901)
U .M.
Height mm 1094 - 1281
Width mm 709
Depth mm 649
Weight Kg 163
Diameter of smoke exhaust duct mm 80
Max. volume of heating m
3
243 (90m
2
)
Min.-max. calorific power Kw/h 2,5 - 11
Min.-max. hourly consumption of pellets Kg/h 0,5 - 2,4
Electrical power absorbed during operation W 110
Supply V - Hz 220 - 50
Tank capacity Kg 17
Min.-max. autonomy h 6,8 - 34
The data shown above are indicative and not binding. Ecoteck reserves the right to make any modifications for the purpose of
improving the performances of the product.
The data referring to hourly consumption and autonomy have been calculated considering a pellet yield of: 1 kg= 4,7 Kw/h.
500
U .M.
Height mm
459
Width mm
461
Depth mm
481,5
Weight Kg
55
Diameter of smoke exhaust duct mm
80
Max. volume of heating m
3
162 (60 m
2
)
Min.-max. calorific power Kw/h
2,5 - 7,5
Min.-max. hourly consumption of pellets Kg/h
0,5 - 1,6
Electrical power absorbed during operation W
110
Supply V - Hz
220 - 50
Tank capacity Kg
8
Min.-max. autonomy h
5 - 16
The data shown above are indicative and not binding. Ecoteck reserves the right to make any modifications for the purpose of
improving the performances of the product.
The data referring to hourly consumption and autonomy have been calculated considering a pellet yield of: 1 kg= 4,7 Kw/h.
INTERNAL FLUE
Lairtight steel sheeting
Covering plate
YES
45° bend, diam.80
Fig.9
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ravelli 550 Erika at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ravelli 550 Erika in the language / languages: English, German, Danish, French, Italian, Spanish as an attachment in your email.

The manual is 10,04 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info