2. Specifications
ToxiRAE Pro Specifications
118 mm x 60 mm x 30 mm (4.6" x 2.4" x 1.2")
220g (7.76 oz)
Over 20 intelligent interchangeable field-replaceable electrochemical sensors
Rechargeable Li-ion battery
• Operating time > 30 hours (normal operation)
• Recharge time < 4 hours through charging cradle
Graphical LCD display with white LED backlighting (activated when monitor
is in alarm or with a button press)
Real-time reading of concentrations in parts per million; battery status;
datalogging on/off status; wireless on/off and reception quality; STEL, TWA,
and peak values (as applicable)
2 buttons for operation and programming
Diffusion
Automatic with AutoRAE 2 Test and Calibration Station or manual
Wireless remote alarm notification, audible (95dB @ 30cm), vibration, visible
alarm (flashing bright red LEDs), and on-screen indication of alarm conditions
• Additional diagnostic alarm and display message for low battery
• Continuous Datalogging with a three-month capacity (at one-minute
intervals)
• User-configurable datalogging interval (from 1 to 3,600 seconds)
and Data
Download
• Data download and instrument set-up on PC via charging and PC
communication cradle
• Data download via AutoRAE 2 Automated Test and Calibration Station
• Wireless data and status transmission via built-in RF modem (optional)
RAE Systems Dedicated Wireless Network
ISM license-free bands
300 feet (100 meters)
-4° to 131° F (-20° to 55° C)
0 to 95% relative humidity (non-condensing)
Resistance
IP-65 rating for dust and water ingress protection (validated by an independent
test laboratory)
Hazardous
Location
Approvals
US and Canada
Class I, Div. 1; Groups A,B,C,D T4
Class I, Zone 0 A/Exia IIC T4
Europe
ATEX: II 1G, Ex ia IIC Ga T4
IECEx: Ex ia IIC Ga T4
China
Ex ia IIC T4
(European
Conformity)
EMC directive: 2004/108/EC
R&TTE directive: 1999/5/EC
ATEX directive: 94/9/EC
Two years on non-consumable components and CO, H
2
S, and O
2
sensors
One year on all other sensors, battery, and consumable parts
Specifications are subject to change.
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for RAE Systems ToxiRAE Pro at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of RAE Systems ToxiRAE Pro in the language / languages: English as an attachment in your email.

The manual is 2,3 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info